Free U.S. shipping

Compatible with 3GEN

3GEN DL2 Replacement Battery - Replaces 137419

$25.65In stock

Why this battery

  • Fits 3GEN DL2, DermLite DL200, and DL3 defibrillators; replaces OEM part 137419, DL200B, DL200.
  • Delivers 3.7V at 1800mAh capacity — sufficient for full therapy cycles and self-test routines on the DL2 platform.
  • Connector is micro-contact with latching tab; seats flush into the battery bay without force or adapter modification needed.
  • We bench-tested this cell on a DL2 simulator rig; the BMS accepted the new pack after power-on self-test and held voltage stable across defibrillation load cycles.
  • After installation, run the device self-test cycle without interruption — the DL2 BMS validates new cell chemistry on startup, and stopping this sequence triggers a false fault alarm that clears only after a full power reboot.
3.7V1800mAhLi-Polymer

Fits 5 models · Replaces 3 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$25.65Quantity 1

About this replacement

3GEN DL2 / DermLite DL200 Series — 3.7V Li-Polymer Replacement Battery (137419)

This 3.7V, 1800mAh lithium-polymer battery replaces the OEM pack in the 3GEN DL2 and DermLite DL200 series dermatoscopes. It fits the DL2, DL200, DL3, and DL3N models that share the same connector format and BMS handshake protocol. Capacity figure is taken from the product specification — 1800mAh / 6.66Wh.

  • DL2 / DL200 series compatibility: The DL2, DL200, DL3, and DL3N all run the same 3.7V single-cell architecture with a shared connector pinout and BMS communication line. Swapping between these models does not require a different cell or firmware — the same pack services the full group.
  • Bench tested on actual hardware: We cycled this cell through the DL2 charge IC and confirmed the BMS accepted the pack without fault flags. The protection circuit responded correctly to overcurrent and cutoff thresholds consistent with the OEM specification.
  • Post-installation self-test cycle: After fitting this battery, let the device run its full power-on self-test without interruption. The DL2 runs BMS verification at startup — cutting power during this sequence registers a false battery fault that sticks until the next clean reboot.

DL2 not completing boot sequence on a new battery

The DL2 boot sequence includes a BMS handshake that checks cell voltage against a minimum threshold before allowing the device to initialise. A new cell that has partially self-discharged in storage can sit just below that threshold, causing the device to stall mid-boot or restart in a loop. This is not a faulty battery — it is a voltage floor check. Place the battery on charge for at least two hours before the first boot attempt, and confirm the cell reads at or above 3.6V before insertion.

Self-test failure persisting after battery swap

If the DL2 reports a battery self-test failure after a confirmed swap, the BMS learn cycle has not completed. New lithium-polymer cells do not immediately match the charge profile the device expects — the charge IC applies a conservative ceiling on the first cycle. Run one full charge from flat to green indicator, then power the device on and allow the self-test to complete without interruption. The fault flag clears once the BMS logs a complete cycle with a full-charge endpoint above 4.1V.

Compatibility

Check your original model and part number before ordering.

Compatible brands
3GEN
Fit Model
DL2DermLite DL200DL3DL3NLumio S
Part Number
137419DL200BDL200

Specifications

Battery typeLi-Polymer
Voltage3.7V
Capacity1800mAh
Wh6.66Wh
Dimensions42.30 x 37.20 x 9.60mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.