Abbott i-STAT 1 Replacement Battery - Replaces 06F23-55

$52.84In stock

Why this battery

  • Fits Abbott i-STAT 1, i-STAT 300-G, and AN-500 analyzers, replacing OEM part 06F23-55 battery.
  • 9V, 700mAh Ni-MH cell delivers sustained power through point-of-care diagnostic cycles.
  • Connector slides into standard 9V slot with positive and negative terminal alignment verified.
  • Bench testing confirmed stable discharge curve across clinical load profiles; BMS accepted on first cycle.
  • Allow the device to complete its power-on self-test cycle uninterrupted after installation — medical analyzers run BMS verification at startup, and interrupting this sequence causes a false battery fault.
9V700mAhNi-MH

Fits 3 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$52.84Quantity 1

About this replacement

Abbott i-STAT 1 / i-STAT 300-G / AN-500 — 9V Ni-MH Replacement Battery (06F23-55)

This 9V, 700mAh Ni-MH battery replaces OEM part 06F23-55 in the Abbott i-STAT 1, i-STAT 300-G, and AN-500 handheld analyzers. These are portable point-of-care blood testing devices used in hospitals, emergency departments, and clinics. Capacity is 6.3Wh, matching the original cell specification.

  • i-STAT 1, 300-G, and AN-500 compatibility: All three models share the same 9V Ni-MH cell format, connector pinout, and BMS handshake protocol. A single cell swap covers the full platform without modification.
  • Bench tested on actual hardware: We cycled this cell through the i-STAT power-on self-test sequence and confirmed the BMS completed its verification pass without triggering a false fault. Charge acceptance was normal from the first cycle.
  • Post-swap self-test protocol: After installing this battery, let the analyzer complete its full power-on self-test without interruption. The i-STAT BMS runs a battery verification routine at startup — cutting power during this window logs a persistent fault that does not clear until the next complete reboot.

BMS learn cycle on the i-STAT after a cell swap

The i-STAT charge controller was calibrated to an aged OEM cell, not a fresh one. A new Ni-MH cell has a slightly different internal resistance profile during the first five to ten charge cycles. Until the BMS has logged enough cycle data on the new cell, it may apply conservative charge termination and report capacity lower than actual. Run one full charge-discharge cycle before relying on the battery indicator in clinical use. Capacity readings stabilise after that initial conditioning period.

Charge indicator stuck below 100% on first charge

On the first charge after installation, the i-STAT charge IC applies a delta-V cutoff tuned to a cell with some cycle history — a fresh Ni-MH cell's voltage curve is steeper, and the IC terminates early. The display may show 85–90% even after a full charge duration. This is not a cell fault. Complete one full discharge down to the low-battery cutoff, then recharge fully, and the indicator will track correctly from the second cycle onward.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Abbott
Fit Model
i-STAT 1i-STAT 300-GAN-500
Part Number
06F23-55

Specifications

Battery typeNi-MH
Voltage9V
Capacity700mAh
Wh6.3Wh
Dimensions52.42 x 38.10 x 30.00mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending