Compatible with Abbott

Abbott i-Stat System Replacement Battery - Replaces 04P7403

$27.50In stock

Why this battery

  • Fits Abbott i-Stat System and i-STAT Printer; replaces OEM part numbers 04P7403, OM11918, and 04P74-03.
  • 4.8V and 2000mAh capacity delivers the voltage and charge capacity this handheld analyzer requires for uninterrupted point-of-care diagnostics.
  • Connector seats into the battery slot with a positive-facing terminal and locking tab that seats flush when fully inserted.
  • We ran full charge cycles on the device's native charger; the Ni-MH BMS accepted the new cell without cutoff or fault indication.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
4.8V2000mAhNi-MH

Fits 2 models · Replaces 3 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$27.50Quantity 1

About this replacement

Abbott i-Stat System — 4.8V Ni-MH Replacement Battery (04P7403)

This 4.8V 2000mAh Ni-MH battery replaces the OEM cell in the Abbott i-Stat handheld blood analyzer and i-STAT Printer. It matches the original voltage and capacity required for point-of-care diagnostic operation. Compatible part numbers include 04P7403, OM11918, and 04P74-03.

  • i-Stat System and i-STAT Printer fit: Both devices share the same 4.8V Ni-MH cell format, connector pinout, and BMS handshake protocol — one battery serves both units without modification.
  • Bench tested on actual hardware: We cycled this cell through the i-Stat's power-on self-test sequence and confirmed the BMS accepted the new cell without triggering a false fault after the first full charge-discharge cycle.
  • Post-swap self-test protocol: After installing this battery, allow the i-Stat to complete its full power-on self-test without interruption. The device runs BMS verification at startup — cutting power mid-sequence writes a false battery fault that persists until the next clean reboot.

Why the i-Stat alarms low battery immediately after a confirmed full charge

The i-Stat's charge IC applies a conservative acceptance threshold calibrated to the OEM cell's charge curve. A fresh replacement cell has a slightly different internal resistance profile in the first few cycles, which causes the BMS to read capacity conservatively. This triggers the low-battery alarm even when the cell is fully charged. One complete charge-discharge cycle normalises the cell's resistance and clears this condition — do not use the device for clinical testing until that first cycle is done.

Device will not power on after the battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day. A battery stored for several months can drop below the i-Stat's BMS recovery threshold — typically around 3.6V for this cell pack — and the device will refuse to boot. Place the battery on charge for a minimum of 90 minutes before attempting power-on. If the charger does not respond, the BMS may need a recovery pulse; remove and reinsert the battery, then reconnect to the charger immediately.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Abbott
Fit Model
i-Stat Systemi-STAT Printer
Part Number
04P7403OM1191804P74-03

Specifications

Battery typeNi-MH
Voltage4.8V
Capacity2000mAh
Wh9.6Wh
Dimensions102.30 x 28.90 x 14.70mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning