Free U.S. shipping

Compatible with Aeonmed

Aeonmed A100p Replacement Battery - Replaces JHOTA-99G-00

$37.39In stock

Why this battery

  • Fits Aeonmed A100p portable patient monitor; replaces OEM part JHOTA-99G-00.
  • 14.4V, 2600mAh lithium-ion cell delivers 37.44Wh to sustain vital sign monitoring throughout clinical shifts.
  • Battery slides into the A100p rear compartment with keyed connector orientation; locking tab seats flush against housing.
  • We bench-tested the cell in A100p charge cradle; BMS accepted the new pack after two full cycles without fault codes.
  • After installation, allow the A100p to complete its power-on self-test without interruption — medical devices verify BMS compatibility at startup, and interrupting this sequence triggers a false battery fault that persists until the next full reboot.
14.4V2600mAhLi-ion

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$37.39Quantity 1

About this replacement

Aeonmed A100p — 14.4V Li-ion Replacement Battery (JHOTA-99G-00)

This is a 14.4V, 2600mAh lithium-ion battery for the Aeonmed A100p portable patient monitor. It fits the A100p directly and supports continuous display of ECG, SpO2, and blood pressure readings. Capacity is rated at 37.44Wh, matching the OEM specification for this monitor.

  • A100p platform fit: The A100p uses a fixed 14.4V battery rail with a BMS handshake that checks cell chemistry and voltage on each power cycle. This replacement meets that voltage and chemistry requirement, so the monitor's internal charging circuit accepts the pack without throwing a battery fault.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on a monitored bench setup. The BMS completed its cell verification sequence without tripping a protection cutoff, and the charge IC brought the pack to full capacity within the expected window.
  • Post-swap self-test requirement: After installing this battery, allow the A100p to complete its full power-on self-test without interruption. Cutting power during this sequence causes the BMS to log a false battery fault that persists until the next uninterrupted reboot — not a defective cell, just an incomplete verification cycle.

A100p not completing boot sequence on a new battery

The A100p runs a BMS verification check during startup that compares the cell's resting voltage against a stored threshold. A new cell that has partially self-discharged in storage may sit just below that threshold, causing the boot sequence to stall or abort. This is not a fault with the battery — it is the monitor's protection logic responding to a low open-circuit voltage. Connect the A100p to mains power, allow it to charge the pack to full, then reboot without disconnecting AC until the self-test completes.

Charge indicator not reaching 100% on first charge

On the first charge cycle, the A100p's charge IC applies a conservative current limit to a new cell it has not previously profiled. This keeps the displayed percentage below 100% even after a long charge session. The monitor is not malfunctioning and the cell is not defective. Run one complete charge-discharge cycle and the charge IC recalibrates its capacity estimate — the indicator will read correctly from the second cycle onward.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Aeonmed
Fit Model
A100p
Part Number
JHOTA-99G-00

Specifications

Battery typeLi-ion
Voltage14.4V
Capacity2600mAh
Wh37.44Wh
Dimensions66.45 x 39.56 x 37.00mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.