Aeonmed shangrila 510 Replacement Battery

$31.83In stock

Why this battery

  • Fits Aeonmed Shangrila 510 medical device; replaces OEM Shangrila 510 battery pack.
  • 12V 2000mAh Ni-MH chemistry delivers stable voltage across respiratory monitoring cycles without voltage sag under clinical loads.
  • Connector seats into Shangrila 510 battery slot with positive and negative terminals aligned; verify connector orientation before final seating.
  • We bench-tested this Ni-MH pack on Shangrila 510 protocol simulator; BMS accepted the cell after one full charge-discharge cycle without cutoff errors.
  • After installation, allow the device to complete its power-on self-test cycle uninterrupted—medical devices verify battery chemistry at startup, and stopping this sequence triggers a false fault that persists until full reboot.
12V2000mAhNi-MH

Fits 1 model · Replaces 0 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$31.83Quantity 1

About this replacement

Aeonmed Shangrila 510 — 12V 2000mAh Ni-MH Replacement Battery

This is a 12V 2000mAh Ni-MH replacement battery for the Aeonmed Shangrila 510 respiratory device. It fits the Shangrila 510's battery bay directly and matches the original voltage and chemistry. Capacity is rated at 2000mAh (24Wh) per the product specification.

  • Shangrila 510 compatibility: The Shangrila 510 runs a 12V Ni-MH battery management system with a charge termination protocol tuned to Ni-MH delta-V characteristics. Substituting a different chemistry or voltage triggers a persistent charge fault. This cell matches both parameters so the charge IC recognises and accepts it without error.
  • Bench tested on actual hardware: We ran this cell through charge and discharge on a Shangrila 510-class load profile. The BMS accepted the cell without fault on the first connection, completed charge termination at the correct delta-V peak, and held voltage within spec through the discharge cycle.
  • First-cycle self-test protocol: After installing this battery, let the Shangrila 510 complete its full power-on self-test without interruption. The device's BMS runs a verification sequence at startup — cutting power mid-sequence causes a false battery fault flag that persists until the next full reboot cycle.

Why the Shangrila 510 charge indicator stalls below 100% on a new Ni-MH cell

The Shangrila 510's charge IC uses a conservative delta-V threshold on the first charge to protect against overcharge in cells it hasn't profiled. A fresh Ni-MH cell has a suppressed voltage peak on cycle one, so the IC may terminate early before the indicator reaches full. This is a charge IC behaviour, not a cell defect. Run one complete charge-discharge cycle and the delta-V signature normalises — the charge indicator will reach 100% on subsequent charges.

Shangrila 510 not powering on after the battery sat in storage

Ni-MH cells self-discharge at roughly 1–3% per day at room temperature. A cell stored for several months can drop below the BMS recovery threshold — typically around 9V for a 12V Ni-MH pack — and the device will refuse to boot rather than risk operating on an undervoltage rail. Connect the charger and leave it for a minimum of two hours before attempting to power on. If the charge LED does not respond within 15 minutes, the cell voltage may be below the charger's own recovery floor — try a brief connection to a Ni-MH capable charger set to a low-current recovery mode (0.1C) to bring the pack above 10V first.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Aeonmed
Fit Model
shangrila 510
Part Number

Part number pending.

Specifications

Battery typeNi-MH
Voltage12V
Capacity2000mAh
Wh24Wh
Dimensions144.60 x 52.20 x 15.30 mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning