Why this battery

  • Fits Air Liquide Blease 5500 Osiris 3 and Taema Osiris 3 ventilators, replacing OEM part YR109301.
  • 9.6V, 1500mAh Ni-MH chemistry delivers stable voltage to control circuits and backup power functions.
  • Connector slides into the battery slot with a single locking tab; orient the contact plate toward the device receptacle.
  • We bench-tested the cell on a medical-grade charger profile; the BMS accepted the charge curve without throttling or fault flags.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — the Osiris platform verifies Ni-MH chemistry on startup, and stopping this sequence triggers a false battery fault that persists until full reboot.
9.6V1500mAhNi-MH

Fits 3 models · Replaces 2 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$49.75Quantity 1

About this replacement

Air Liquide Blease 5500 Osiris 3 — 9.6V Ni-MH Replacement Battery (YR109301)

This is a 9.6V, 1500mAh Ni-MH replacement battery for the Blease 5500 Osiris 3 anesthesia workstation. It also fits the Taema Respirator Osiris 3 and Ventilator Osiris 3 platforms. OEM part numbers YR109301 and YR109301031404 both apply to this cell configuration.

  • Osiris 3 platform fit: The Blease 5500, Taema Respirator, and Ventilator Osiris 3 share the same battery bay geometry, voltage rail, and connector. All three draw from this 9.6V cell to maintain control system function and backup power during mains interruption.
  • Bench tested on actual hardware: We cycled this battery through charge and load sequences matching the Osiris 3's backup draw profile. The BMS accepted the cell without fault codes on a conditioned unit after one full charge-discharge cycle.
  • Post-installation self-test protocol: After fitting this battery, allow the Osiris 3 to complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power during this step generates a false battery fault that persists until the next clean reboot.

Self-test failure after battery swap on the Osiris 3

The Osiris 3 runs an internal BMS learn cycle during its first few charge-discharge sequences with a new cell. A fresh Ni-MH battery has not yet established the internal resistance baseline the device expects. If the self-test fails immediately after installation, run one full charge-discharge cycle outside clinical use before relying on the battery. This gives the BMS enough data to set accurate state-of-charge thresholds.

Charge indicator not reaching 100% on the first charge after installation

On the first charge, the Osiris 3's charge IC applies a conservative current limit against a new Ni-MH cell — this is normal behaviour, not a cell fault. The indicator typically stalls below full because the charge algorithm hasn't confirmed the cell's peak voltage signature yet. Run a complete charge cycle, then discharge under normal standby load, and repeat once. By the second charge the indicator should reach the full threshold consistently.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Air Liquide
Fit Model
Blease 5500 Osiris 3Taema Respirator Osiris 3Ventilator Osiris 3
Part Number
YR109301YR109301031404

Specifications

Battery typeNi-MH
Voltage9.6V
Capacity1500mAh
Wh14.4Wh
Dimensions56.80 x 50.30 x 28.50mm