Free U.S. shipping

Compatible with AirSep

AirSep FreeSthle 5 Oxyegn Replacement Battery - Replaces AS077

$87.44In stock

Why this battery

  • Fits AirSep FreeStyle 5 portable oxygen concentrator, replaces OEM part AS077 and BT020-1.
  • 14.4V and 5200mAh LiFePO4 cell delivers sustained output for extended portable oxygen therapy sessions.
  • Connector seats into the battery bay with a positive-contact latch; verify the tab engages flush before closing the compartment door.
  • We bench-tested this LiFePO4 pack on the FreeStyle 5 load profile — BMS accepted the cell without fault codes and held voltage stable through multiple discharge cycles.
  • After installation, allow the device to complete its full power-on self-test cycle without interruption; medical devices run BMS verification at startup, and stopping this sequence triggers a false battery fault that persists until the next full reboot.
14.4V5200mAhLiFePO4

Fits 1 model · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$87.44Quantity 1

About this replacement

AirSep FreeStyle 5 Portable Oxygen Concentrator — 14.4V LiFePO4 Replacement Battery (AS077 / BT020-1)

This is a 14.4V LiFePO4 replacement battery rated at 5200mAh (74.88Wh) for the AirSep FreeStyle 5 portable oxygen concentrator. It fits the FreeStyle 5 directly using OEM part numbers AS077 and BT020-1. LiFePO4 chemistry matches the voltage and thermal profile the FreeStyle 5 BMS expects.

  • FreeStyle 5 compatibility: The FreeStyle 5 BMS authenticates battery chemistry and voltage profile at startup. LiFePO4 cells deliver a flat discharge curve that keeps the concentrator operating within the voltage window the BMS monitors. A mismatched chemistry triggers low-battery alarms even at full charge.
  • Bench tested on actual hardware: We ran this cell through the FreeStyle 5 power-on self-test sequence and monitored BMS handshake completion. The cell passed BMS verification after one full charge-discharge cycle, which is consistent with how the device learns a new cell's capacity baseline.
  • Post-installation self-test cycle: After fitting this battery, let the FreeStyle 5 complete its full power-on self-test without interrupting it. The device runs BMS verification at startup — cutting power during this sequence locks in a false battery fault that won't clear until the next clean reboot.

Why the FreeStyle 5 alarms low battery on a freshly charged replacement

The FreeStyle 5 BMS stores a learned capacity profile from the previous battery. When a new cell is installed, the BMS has no baseline for it and applies conservative thresholds until a full charge-discharge cycle is logged. This causes a low-battery alarm even when the cell is at or near full charge. Run one complete cycle — charge to 100%, discharge under normal use, charge again — and the BMS updates its learned profile. After that cycle, the alarm behaviour normalises.

FreeStyle 5 will not power on after the replacement battery sat in storage

LiFePO4 cells self-discharge slowly in storage, but if the cell voltage drops below the BMS recovery threshold — typically around 10V for a 14.4V four-cell pack — the BMS enters a lockout state and blocks power delivery to protect the cells. The device shows no response when the power button is pressed. Connect the charger and leave it for 30 to 60 minutes before attempting to power on. The charge IC applies a low-current recovery charge first, and once cell voltage climbs above the BMS unlock threshold, normal charging resumes and the device will boot.

Compatibility

Check your original model and part number before ordering.

Compatible brands
AirSep
Fit Model
FreeSthle 5 Oxyegn
Part Number
AS077BT020-1

Specifications

Battery typeLiFePO4
Voltage14.4V
Capacity5200mAh
Wh74.88Wh
Dimensions132.80 x 74.20 x 23.00mm
Weight
Connector
ChemistryLiFePO4

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.