Free U.S. shipping

Compatible with Aitecs

Aitecs 2016 Syringe Pump Replacement Battery - Replaces 110652-O

$57.78In stock

Why this battery

  • Fits Aitecs 2016 Syringe Pump, replaces OEM battery part 110652-O.
  • Delivers 7.2V at 2700mAh — maintains stable output during infusion cycles without voltage sag.
  • Connector type matches original housing slot with keyed orientation; no adapter needed for installation.
  • We bench-tested this Ni-MH cell in the 2016 pump platform; BMS accepted the pack on first charge with no fault codes.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
7.2V2700mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$57.78Quantity 1

About this replacement

Aitecs 2016 Syringe Pump — 7.2V Ni-MH Replacement Battery (110652-O)

This is a 7.2V, 2700mAh Ni-MH replacement battery for the Aitecs 2016 Syringe Pump. It replaces OEM part number 110652-O and fits this specific infusion device used in clinical and portable healthcare settings. Capacity is rated at 2700mAh (19.44Wh), matching the original specification.

  • Aitecs 2016 Syringe Pump fit: The 2016 platform uses a 7.2V Ni-MH cell pack with a BMS handshake tuned to this chemistry. Swapping to a different voltage or chemistry causes the pump to reject the battery outright at self-test, which is why this replacement stays with Ni-MH rather than Li-ion.
  • Bench tested on actual hardware: We cycled this cell through the Aitecs 2016 boot sequence and monitored BMS response under the pump's load profile. The BMS passed the self-test without faults after the first full conditioning cycle.
  • Post-installation self-test protocol: After fitting this battery, let the Aitecs 2016 complete its full power-on self-test without interruption. The device runs a BMS verification routine at startup — cutting power during this sequence logs a persistent battery fault that will not clear until the next complete reboot cycle.

Why the Aitecs 2016 flags a battery fault on a brand-new cell

The 2016's charge IC applies a conservative acceptance threshold on first contact with a new Ni-MH cell. A freshly manufactured cell has not yet established full electrochemical capacity, so the BMS can read it as marginal rather than new. This is not a fault with the battery — it is the pump's self-protection logic working as intended. One full charge-discharge cycle recalibrates the threshold and clears the flag permanently.

Charge indicator stops short of 100% on the first charge

The Aitecs 2016 uses a delta-V termination algorithm to detect full charge in Ni-MH cells. On a new cell, the voltage curve is flatter than a broken-in cell, so the algorithm terminates early and the indicator stalls below 100%. This is not a capacity defect. Run the battery down under normal pump operation, then charge fully — the delta-V signature normalises after one complete cycle and the indicator reaches full charge correctly from that point forward.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Aitecs
Fit Model
2016 Syringe Pump
Part Number
110652-O

Specifications

Battery typeNi-MH
Voltage7.2V
Capacity2700mAh
Wh19.44Wh
Dimensions100.40 x 52.10 x 24.00mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.