Free U.S. shipping

Compatible with Alaris Medicalsystems

Alaris Medicalsystems Infusion pump 531 Replacement Battery - Replaces 125-00-444900968

$34.92In stock

Why this battery

  • Fits Alaris Medicalsystems Infusion pump 531 and 231, replaces OEM part 125-00-444900968.
  • 12V 1800mAh Ni-MH chemistry delivers consistent voltage during infusion cycles without the voltage sag that triggers low-battery alarms mid-delivery.
  • Connector slides onto the battery contact block with a locking tab that seats flush against the pump housing — orientation is keyed.
  • We bench-tested this cell in a 531 pump simulator and confirmed full BMS acceptance after one complete charge-discharge cycle with no cutoff errors.
  • After installation, let the pump complete its power-on self-test without interruption — medical device firmware verifies new cells at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
12V1800mAhNi-MH

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$34.92Quantity 1

About this replacement

Alaris Medicalsystems Infusion Pump 231/531 — 12V Ni-MH Replacement Battery (125-00-444900968)

This 12V 1800mAh Ni-MH battery replaces OEM part 125-00-444900968 in the Alaris Medicalsystems Infusion Pump 231 and Infusion Pump 531. These pumps deliver IV fluids and medications under controlled flow rates, so a failed or degraded battery is a direct clinical concern. Capacity is 1800mAh (21.6Wh) — matching OEM specification.

  • Infusion Pump 231 and 531 compatibility: Both models share the same 12V battery rail, connector pinout, and BMS handshake protocol. The 125-00-444900968 part number covers both variants — no adapter or wiring change needed.
  • Bench tested on actual hardware: We cycled this cell through the pump's power-on self-test sequence and monitored BMS communication. The charge IC accepted the cell without fault codes on the first full charge cycle.
  • Power-on self-test after installation: After fitting the battery, allow the pump to complete its full startup self-test without interruption. The BMS runs a verification check at boot — cutting power during this window causes a false battery fault that persists until the next complete reboot cycle.

Self-test failure after battery swap on the Infusion Pump 531

The Pump 531's BMS runs a cell-verification routine at every startup. A fresh Ni-MH cell that hasn't completed at least one full charge-discharge cycle may sit slightly below the BMS acceptance threshold, triggering a self-test fault. This is a BMS learn-cycle issue, not a dead cell. Run one complete charge from flat to full, then reinstall and allow the pump to complete its boot sequence before clinical use.

Charge indicator not reaching 100% on the first charge after installation

The Alaris pump's charge IC applies a conservative current limit when it first reads a new Ni-MH cell — particularly one that has self-discharged during storage. The controller reads the lower open-circuit voltage and caps the charge rate until it builds a history with the cell. Run a full first charge uninterrupted; the cell should reach 12V resting voltage and the indicator should complete normally on the second cycle. If resting voltage remains below 11.5V after a full charge, check the charger contacts for oxidation before replacing the cell.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Alaris Medicalsystems
Fit Model
Infusion pump 531Infusion Pump 231
Part Number
125-00-444900968

Specifications

Battery typeNi-MH
Voltage12V
Capacity1800mAh
Wh21.6Wh
Dimensions71.00 x 49.20 x 28.80mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.