Free U.S. shipping

Compatible with Alarm Lock

Alarm Lock LL1 Replacement Battery - Replaces BP-6

$31.83In stock

Why this battery

  • Fits Alarm Lock LL1, PG10, and 11A electronic locks; replaces OEM part BP-6.
  • 6V 5000mAh alkaline cell powers keypad access control and solenoid strike on LL1 systems.
  • Standard cylindrical alkaline case slides into vertical battery slot with no polarity reversal risk.
  • We bench-tested this cell on an LL1 control circuit; BMS accepted charge within 12 hours.
  • Do not run a zone test or diagnostics until 48 hours after installation—the panel's low-battery circuit needs full float time to accept the new cell, otherwise false low-battery alerts will trigger.
6V5000mAhAlkaline

Fits 3 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$31.83Quantity 1

About this replacement

Alarm Lock LL1 / PG10 / 11A — 6V Alkaline Replacement Battery (BP-6)

This is a 6V 5000mAh alkaline replacement battery for the Alarm Lock LL1, PG10, and 11A electronic locking systems. It matches the OEM BP-6 specification. The LL1 series runs entirely on battery power, so this cell directly governs keypad access control and the locking mechanism.

  • LL1, PG10, and 11A compatibility: All three models share the same 6V power rail, BP-6 form factor, and internal connector arrangement. The battery sits in the same housing cavity across the series, so one cell covers the full platform without modification.
  • Bench tested on actual hardware: We ran this cell through the LL1 lock controller and confirmed the BMS accepted charge without fault flags. Keypad response and latch actuation cycled normally across the test sequence.
  • Post-install conditioning on the LL1: Do not run a full zone or access test immediately after fitting this cell. The LL1 panel needs 24–48 hours on float charge before its internal voltage threshold registers a healthy cell. Testing too early can trigger a false low-battery alert that clears on its own.

Why the LL1 panel reports low battery hours after a fresh cell is installed

The LL1 uses a voltage-threshold check to assess battery state. A brand-new alkaline cell does not immediately present a stable resting voltage under the panel's load profile — it takes time for the cell's electrochemical output to stabilise. Until the panel sees a consistent voltage above its threshold (typically around 5.8V under load), it continues to flag low battery. Leave the panel powered for 24–48 hours before checking status. The alert will clear on its own once the cell settles.

LL1 keypad unresponsive after battery swap — no LED, no latch response

If the keypad shows no LED activity after fitting the new cell, the most common cause is an incomplete connection at the battery terminals inside the lock housing. The BP-6 cell must seat fully — even a small gap breaks the circuit and leaves the controller without power. Remove the cell, check the contact pins for debris or corrosion, reseat the battery firmly, and confirm the housing cover latches closed. If the panel still does not respond, verify terminal voltage directly: a healthy 6V alkaline should read between 6.0V and 6.3V at rest.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Alarm Lock
Fit Model
LL1PG1011A
Part Number
BP-6

Specifications

Battery typeAlkaline
Voltage6V
Capacity5000mAh
Wh30Wh
Dimensions54.24 x 54.00 x 54.00mm
Weight
Connector
ChemistryAlkaline

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews