Free U.S. shipping

Compatible with Ascom

Ascom Myco Replacement Battery - Replaces 490926A

$29.36In stock

Why this battery

  • Fits Ascom Myco, Myco SH1 VoWiFi, and SH1-ABAA handsets; replaces OEM part 490926A and RB-490926-LW.
  • 3.7V, 1750mAh lithium-ion cell delivers full handset runtime across hospital floors and clinical zones.
  • Flat connector seats into the battery slot with a single locking tab; no polarity risk on insertion.
  • We bench-tested this cell in the Myco charge cradle; BMS accepted the new chemistry on first cycle without fault codes.
  • After installation, let the device complete its power-on self-test without interruption — medical handsets verify BMS chemistry at startup, and stopping this cycle triggers a false battery fault until full reboot.
3.7V1750mAhLi-ion

Fits 4 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$29.36Quantity 1

About this replacement

Ascom Myco SH1 Series — 3.7V Li-ion Replacement Battery (490926A)

This is a 3.7V, 1750mAh Li-ion battery for the Ascom Myco wireless handset. It fits the Myco, Myco SH1 VoWiFi, SH1-ABAA, and SH1-ABAA/F models used in hospital and clinical communication systems. Also cross-references OEM part RB-490926-LW.

  • Myco SH1 platform compatibility: The SH1-ABAA and SH1-ABAA/F share the same 3.7V battery bay, connector pinout, and BMS handshake protocol. One cell fits all four model variants without modification.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on an SH1 handset. The BMS accepted the cell on first insertion, completed voltage verification, and held the charge curve within the expected range for Li-ion at this capacity.
  • Post-swap self-test protocol: After installing this battery, let the Myco complete its full power-on self-test without pressing any keys or interrupting the boot sequence. The BMS runs a chemistry verification step at startup. Interrupting it logs a false battery fault that persists until the next full reboot.

Why the Myco alarms low battery immediately after a confirmed full charge

The Myco's BMS stores learned thresholds calibrated to the original cell's charge curve. A new cell with a slightly different internal resistance profile can read below the BMS alarm threshold on the first cycle, even at full charge. This is not a fault with the replacement cell. Run one complete charge-discharge cycle and the BMS recalibrates its reference points. The low-battery alarm clears after that first full cycle completes.

Myco handset will not power on after the battery sat in storage

Li-ion cells self-discharge over time. If this battery was stored for several months before installation, its resting voltage may have dropped below the Myco's BMS recovery threshold — typically around 2.5V for this chemistry. The handset will not attempt to boot below that threshold as a protection measure. Place the handset on charge for at least 30 minutes before pressing the power button, giving the charge IC enough time to bring the cell above the minimum recovery voltage before the BMS re-enables the output rail.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Ascom
Fit Model
MycoMyco SH1 VoWiFiSH1-ABAASH1-ABAA/F
Part Number
490926ARB-490926-LW

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity1750mAh
Wh6.48Wh
Dimensions53.50 x 51.40 x 6.80 mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.