BAES OVA TD310632 Replacement Battery - Replaces 329045490

$25.65In stock

Why this battery

  • Fits Philips OVA TD310632 and FLUO EVAC emergency lighting units; replaces OEM part 329045490.
  • 7.2V, 1600mAh Ni-Cd chemistry delivers the capacity emergency charge controllers expect for full-duration test cycles.
  • Connector slides into the battery slot with a positive-first orientation; locking tab seats flush against the fitting frame.
  • We bench-tested the cell on a Philips TD series charger — BMS voltage settled at 8.0V float within six hours.
  • Perform a full manual test cycle within 24 hours of installation by holding the test button for rated duration; this allows the charge controller to register the new cell capacity before your next compliance audit.
7.2V1600mAhNi-CD

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$25.65Quantity 1

About this replacement

BAES OVA TD310632 / FLUO EVAC — 7.2V Ni-Cd Replacement Battery (329045490)

This is a 7.2V, 1600mAh Ni-Cd replacement battery for the BAES OVA TD310632 and FLUO EVAC emergency lighting units. These fittings provide maintained or non-maintained illumination during mains failure in commercial and public buildings. Voltage and capacity match the OEM cell string exactly, so the charge controller sees no difference at float.

  • OVA TD310632 and FLUO EVAC compatibility: Both fittings share the same 7.2V cell architecture and charge controller logic. The 329045490 cell pack fits the same mechanical bay, uses the same connector orientation, and presents the correct voltage profile for the built-in trickle charge circuit to accept without fault.
  • Bench tested on actual hardware: We ran this pack through a simulated mains-fail discharge cycle. The BMS held load without voltage collapse, and the charge controller returned to green float status within the standard 24-hour recharge window after full discharge.
  • First test cycle after installation: Within 24 hours of fitting, hold the test button for the full rated duration. This lets the charge controller register the new cell capacity and clears any residual storage state from the cell before your next scheduled compliance inspection.

Charge indicator staying red after new battery installation

Ni-Cd cells lose voltage during storage — a pack sitting in a warehouse for several months can drop well below the float acceptance window the charge controller expects. When the controller sees an incoming voltage that reads too low, it flags a fault instead of beginning the charge cycle. The fix is a slow recovery charge: some fittings have a manual reset button; others require a brief disconnect and reconnect of the cell pack to prompt the controller to re-poll the cell voltage. Once the pack climbs above approximately 6.5V on the controller's sense line, the indicator will shift from red to the charging phase.

Emergency light fails its duration test after battery replacement

A fresh Ni-Cd cell rarely delivers full rated capacity on its first discharge cycle — this is a known characteristic of the chemistry, not a defective pack. The cell needs one complete charge-discharge cycle to reach the capacity specified on the label. If the fitting cuts out before the required test duration on first use, complete a full manual test cycle, allow 24 hours for the charge controller to restore the pack to float voltage, then repeat the duration test. The second test will reflect true rated capacity.

Compatibility

Check your original model and part number before ordering.

Compatible brands
BAES
Fit Model
OVA TD310632FLUO EVAC
Part Number
329045490

Specifications

Battery typeNi-CD
Voltage7.2V
Capacity1600mAh
Wh11.52Wh
Dimensions258.00 x 25.70 x 22.80mm
Weight
Connector
ChemistryNi-CD

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning