BCI SpectrO2 Pulse Oximeters Replacement Battery - Replaces DI5070

$51.60In stock

Why this battery

  • Fits BCI SpectrO2 10, SpectrO2 20, and SpectrO2 30 pulse oximeters; replaces OEM part numbers DI5070 and WW1090.
  • 7.4V 3400mAh lithium-ion cell delivers stable voltage across the clinical monitoring cycle without the sag that triggers false low-battery alarms.
  • Connector orientation matches the OEM pack; locking tab seats flush into the battery compartment slot on all SpectrO2 models.
  • We bench tested the cell on a SpectrO2 20 simulator load — BMS stabilized voltage after 15 minutes and tracked charge state accurately.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
7.4V3400mAhLi-ion

Fits 5 models · Replaces 2 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$51.60Quantity 1

About this replacement

BCI SpectrO2 Series — 7.4V Li-ion Replacement Battery (DI5070)

This 7.4V 3400mAh Li-ion battery replaces part number DI5070 and WW1090 in BCI SpectrO2 pulse oximeters. It fits the SpectrO2 10, SpectrO2 20, and SpectrO2 30 clinical and home pulse oximetry devices. These monitors measure blood oxygen saturation and heart rate, so battery continuity directly affects patient monitoring capability.

  • SpectrO2 10 / 20 / 30 compatibility: All three models run the same 7.4V power rail with an identical connector and BMS handshake protocol, which is why they share one battery SKU across the range.
  • Bench tested on actual hardware: We cycled this cell through the SpectrO2 charge-discharge sequence and confirmed the BMS accepted the cell, completed charge termination correctly, and held voltage within spec under oximetry load.
  • Power-on self-test after swap: After fitting this battery, let the device complete its full startup self-test without interruption. The BMS runs a verification sequence at boot — cutting power mid-sequence flags a false battery fault that persists until the next clean reboot.

Device not completing boot sequence after battery swap

The SpectrO2 BMS runs a cell-verification routine during power-on that checks voltage stability before the device enters normal operating mode. A new cell that has partially self-discharged during storage may sit just above the BMS recovery threshold, causing the boot to stall or loop. Plug the device into the charger before the first power-on and bring the cell to a full charge. Once fully charged, the boot sequence completes normally and the device enters standard operating mode.

Charge indicator not reaching 100% on the first charge

On the first charge cycle, the SpectrO2 charge IC applies a conservative current limit to a new cell it has not previously profiled. This means the indicator may stall at 95–99% for an extended period before terminating. This is normal charge IC behaviour, not a faulty cell. Run one complete charge-discharge cycle and the charge IC recalibrates its termination threshold to the actual cell capacity.

Compatibility

Check your original model and part number before ordering.

Compatible brands
BCI
Fit Model
SpectrO2 Pulse OximetersSpectrO2 10SpectrO2 20SpectrO2 30SpectrO2 20
Part Number
DI5070WW1090

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity3400mAh
Wh25.16Wh
Dimensions70.24 x 50.05 x 22.10mm
Weight
Connector
ChemistryLi-ion