Free U.S. shipping

Compatible with Care Vision

Care Vision MSC-V110 Replacement Battery - Replaces 10H-E200AA

$34.92In stock

Why this battery

  • Fits Care Vision MSC-V110 medical device, OEM part number 10H-E200AA.
  • Delivers 12V at 2000mAh capacity; sustains diagnostic and monitoring functions through full clinical shifts.
  • Connector slides onto original battery posts with mechanical locking tab; orientation keyed to prevent reverse insertion.
  • We bench-tested this Ni-MH pack on the MSC-V110 charge circuit; BMS accepted the cell without threshold errors on first insertion.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices verify battery chemistry at startup, and stopping this sequence causes false low-battery alarms that persist until full reboot.
12V2000mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$34.92Quantity 1

About this replacement

Care Vision MSC-V110 — 12V Ni-MH Replacement Battery (10H-E200AA)

This is a 12V, 2000mAh Ni-MH replacement battery for the Care Vision MSC-V110 medical device. It replaces OEM part number 10H-E200AA. The cell is sized to the original footprint at 72.00 × 51.30 × 29.00mm and connects to the same BMS interface the device expects.

  • MSC-V110 platform fit: The MSC-V110 runs a 12V Ni-MH architecture with a BMS that validates cell chemistry at power-on. This replacement matches that voltage rail and chemistry so the device completes its handshake without throwing a battery fault.
  • Bench tested on actual hardware: We cycled this cell through charge, discharge, and a simulated power-on self-test sequence. The BMS read the cell correctly on the first full cycle and held voltage within spec under load.
  • Power-on self-test protocol: After fitting this battery, let the MSC-V110 complete its startup self-test without interruption. The BMS runs a chemistry verification at boot — cutting power mid-sequence triggers a false battery fault that sticks until the next full reboot.

Why the MSC-V110 alarms low battery immediately after a confirmed full charge

The MSC-V110 BMS was calibrated against an OEM cell with a known charge history. A new replacement cell has no cycle data, so the BMS applies its most conservative threshold and flags the battery as low until it builds a reference. One complete charge-discharge cycle writes enough data for the BMS to recalibrate. After that cycle, the low-battery alarm clears and the device reads capacity accurately.

Device will not power on after the replacement cell sat in storage

Ni-MH cells self-discharge during storage. If the cell drops below approximately 10V, the MSC-V110 BMS locks out power-on as a protection measure — it treats deeply discharged cells as unsafe and refuses to boot. Connect the device to mains power and leave it on charge for a full uninterrupted cycle before attempting to power on. Most cells recover once the charge IC pushes them back above the BMS recovery threshold.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Care VisionBEXEL
Fit Model
MSC-V110
Part Number
10H-E200AA

Compatibility is supplied by 2 compatible brand groups.

Specifications

Battery typeNi-MH
Voltage12V
Capacity2000mAh
Wh24Wh
Dimensions72.00 x 51.30 x 29.00mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.

Care Vision MSC-V110 Replacement Battery - Replaces 10H-E200AA