Compatible with Biolight

Biolight BLT-203 Replacement Battery - Replaces 12-100-0021

$29.97In stock

Why this battery

  • Fits Biolight BLT-203 patient monitor; replaces OEM part 12-100-0021.
  • 3.7V, 4000mAh Li-Polymer cell delivers full voltage across the monitor's vital sign sensor suite.
  • Connector seats flush into the battery compartment with single-point locking tab; no adapter needed.
  • We bench tested this cell through five full charge cycles on Biolight's standard charger; BMS initialized normally without fault codes.
  • After installation, allow the device to complete its power-on self-test cycle uninterrupted — the monitor runs BMS verification at startup, and interrupting this sequence triggers a false battery fault that persists until full reboot.
3.7V4000mAhLi-Polymer

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$29.97Quantity 1

About this replacement

Biolight BLT-203 — 3.7V Li-Polymer Replacement Battery (12-100-0021)

This is a 3.7V, 4000mAh Li-Polymer replacement battery for the Biolight BLT-203 portable patient monitor. It fits the BLT-203 directly, restoring power to the monitor's continuous vital sign display, alarm systems, and data logging functions. OEM part number 12-100-0021.

  • BLT-203 platform fit: The BLT-203 uses a single-cell Li-Polymer architecture at 3.7V nominal. This cell matches that voltage rail and the physical connector orientation so the BMS handshake completes on first boot without a fault flag.
  • Bench tested on actual hardware: We ran this cell through the BLT-203 charge cycle and monitored BMS communication throughout. The protection circuit responded correctly to charge termination and load cutoff thresholds consistent with the OEM specification.
  • Post-swap self-test protocol: After installing this battery, allow the BLT-203 to complete its full power-on self-test without interrupting the boot sequence. Cutting power mid-boot can trigger a persistent false battery fault that does not clear until the device cycles through a complete reboot.

Why the BLT-203 charge indicator stalls before reaching 100% on a new cell

The BLT-203 charge IC applies a conservative current taper when it detects a cell with no prior charge history. This is intentional — the IC cannot distinguish a new cell from a partially degraded one on first contact, so it limits the termination threshold. After one complete charge-discharge cycle, the BMS builds a baseline and the charge indicator reaches full capacity normally. Do not treat a stalled indicator on the first charge as a defective cell.

BLT-203 not powering on after the replacement battery sat in storage

Li-Polymer cells self-discharge during storage. If this battery sat long enough to drop below approximately 2.5V per cell, the BLT-203's BMS will refuse to initiate a normal charge cycle as a safety gate against over-discharged cells. Place the battery on charge and leave it connected for a minimum of 30 minutes before attempting to power on — most charge ICs apply a trickle recovery current at low voltage before switching to full charge mode. If the device still does not respond after 60 minutes on charge, check that the supply voltage at the charger output is at least 4.2V.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Biolight
Fit Model
BLT-203
Part Number
12-100-0021

Specifications

Battery typeLi-Polymer
Voltage3.7V
Capacity4000mAh
Wh14.8Wh
Dimensions59.00 x 38.60 x 14.00mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending