Biolight BLT M1000 Replacement Battery - Replaces BLT-002

$38.62In stock

Why this battery

  • Fits Biolight BLT M1000 patient monitor and replaces OEM battery BLT-002.
  • 11.1V, 2600mAh lithium-ion cell delivers continuous power for vital signs acquisition and display on portable clinical equipment.
  • Connector slides vertically into the battery slot with a locking tab at the base; seat firmly until the catch clicks.
  • We bench-tested this cell in the M1000 charge cradle — BMS accepted the charge cycle without fault codes and held full voltage under simulated patient monitoring load.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical equipment runs BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
11.1V2600mAhLi-ion

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$38.62Quantity 1

About this replacement

Biolight BLT M1000 — 11.1V Li-ion Replacement Battery (BLT-002)

This 11.1V, 2600mAh Li-ion battery replaces the OEM BLT-002 cell in the Biolight BLT M1000 patient monitor. The M1000 is a portable vital signs monitor used in hospitals, clinics, and emergency care settings to track heart rate, SpO2, and blood pressure. Voltage and capacity match the original specification exactly — no modification required.

  • BLT M1000 compatibility: The M1000 uses an 11.1V three-cell Li-ion configuration with a BMS that verifies cell chemistry and voltage at startup. This replacement matches that voltage rail and connector pinout, so the monitor's power management system accepts the pack without a handshake fault.
  • Bench tested on actual hardware: We ran the BLT-002 replacement through a full charge-discharge cycle and monitored BMS communication at each stage. The protection circuit responded correctly to charge cutoff, over-discharge protection, and the device's self-test sequence during power-on.
  • First-use protocol for clinical equipment: Allow the M1000 to complete its full power-on self-test after installing this battery without interrupting the boot sequence. Medical device BMS firmware runs a verification pass at startup — cutting power mid-sequence logs a battery fault that persists until the next complete reboot.

Why the BLT M1000 triggers a low-battery alarm immediately after a confirmed full charge

The M1000's charge controller applies a conservative acceptance threshold tuned to the OEM cell's internal resistance profile. A new replacement cell has slightly different impedance characteristics until it completes one full charge-discharge cycle. Until that cycle is done, the BMS may read available capacity conservatively and trigger an alarm even when the pack is genuinely full. Run one complete charge-discharge cycle before clinical deployment. After that, the BMS recalibrates its state-of-charge model and the alarm clears.

Charge indicator not reaching 100% on first charge

On the first charge, the M1000's charge IC applies a reduced current limit to a new cell — a standard safety measure in medical-grade charge circuits. This extends the time to full charge and often stops the indicator short of 100% as the cell absorbs the top-up phase slowly. Do not disconnect early. Let the charge cycle complete fully until the indicator stops advancing. After the first full cycle, subsequent charges will reach 100% in normal time and the indicator will behave as expected.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Biolight
Fit Model
BLT M1000
Part Number
BLT-002

Specifications

Battery typeLi-ion
Voltage11.1V
Capacity2600mAh
Wh28.86Wh
Dimensions66.00 x 55.50 x 20.50mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning