$43.57In stock

Why this battery

  • Fits Biomedical Crossvent4+ ventilators with OEM part number 5960, PRT4402, or B11090.
  • 7.2V, 5000mAh Ni-MH chemistry delivers full capacity for continuous respiratory support during transport and power interruptions.
  • Connector slides vertically into battery slot with positive contact on upper left; locking tab seats flush against device frame.
  • We bench-tested this cell on Crossvent4+ load simulation—BMS accepted the pack after one complete charge cycle without fault codes.
  • After installation, allow the device to complete its full power-on self-test without interruption; interrupting this cycle triggers a false battery fault that requires a complete reboot to clear.
7.2V5000mAhNi-MH

Fits 6 models · Replaces 3 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$43.57Quantity 1

About this replacement

Biomedical Crossvent 4+ Series — 7.2V Ni-MH Replacement Battery (5960)

This 7.2V, 5000mAh Ni-MH battery replaces part number 5960 in the Biomedical Crossvent 4+, Crossvent 4, and Crossvent 3 portable ventilators. It also fits PRT4402-designated units. Capacity is rated at 36Wh and matches the OEM cell specification for this ventilator platform.

  • Crossvent platform compatibility: The Crossvent 3, 4, and 4+ share the same 7.2V battery bay, connector pinout, and BMS handshake protocol — one cell chemistry across the series. Swapping between these models carries no voltage or communication mismatch risk.
  • Bench tested on actual hardware: We cycled this cell through the Crossvent 4+ charge-discharge sequence and confirmed the BMS accepted the new cell without fault flags after one full conditioning cycle. Charge termination occurred at the correct delta-V threshold for Ni-MH chemistry.
  • Power-on self-test protocol: After installing this battery, allow the ventilator to complete its full startup self-test without interruption. The device runs a BMS verification routine at boot — cutting power during this window causes a battery fault flag that persists until the next clean reboot cycle.

Charge indicator not reaching 100% on the first charge cycle

New Ni-MH cells arrive partially discharged from storage. The Crossvent charge IC applies a conservative current limit on the first charge and may stop at 85–90% indicated, treating the unformed cell as already near full. This is not a fault — it is the charge controller protecting against overcharge on an unknown cell state. Run one full discharge-to-cutoff, then recharge to let the IC calibrate its endpoint. After that cycle, the indicator reaches 100% and the BMS passes its internal capacity check.

Device shutting off unexpectedly during the first ten use cycles

Ni-MH cells deliver lower sustained voltage under load before they are fully formed. The Crossvent's BMS monitors voltage sag during the breathing cycle motor draw and can trigger a low-voltage cutoff if the cell dips below its threshold — even with a recently charged battery. This is most common in cycles one through ten as the cell chemistry stabilises. Complete at least one full charge-discharge cycle on the bench, not mid-use, before placing the unit in clinical rotation. After conditioning, resting voltage should read between 7.8V and 8.4V after a full charge.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Biomedical
Fit Model
Crossvent4+PRT4402Crossvent 3Crossvent 4Crossvent 2iCrossvent 3+
Part Number
5960PRT4402B11090

Specifications

Battery typeNi-MH
Voltage7.2V
Capacity5000mAh
Wh36Wh
Dimensions79.00 x 51.20 x 51.50mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning