Free U.S. shipping

Compatible with Biosealer

Biosealer CR6 Replacement Battery - Replaces 170-2040

$75.70In stock

Why this battery

  • Fits Biosealer CR6 dental sealant applicator, replaces OEM part 170-2040.
  • 24V, 3700mAh Ni-MH pack delivers consistent power throughout sealant application cycles.
  • Connector attaches vertically into the CR6 battery slot with a positive-lead orientation.
  • We bench-tested this cell in the CR6 charging dock; BMS accepted the new pack on first insertion without fault codes.
  • After installation, let the device complete its power-on self-test cycle without interruption — the CR6 runs BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
24V3700mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$75.70Quantity 1

About this replacement

Biosealer CR6 — 24V Ni-MH Replacement Battery (170-2040)

This is a 24V, 3700mAh Ni-MH replacement battery for the Biosealer CR6 dental sealant applicator. It replaces OEM part number 170-2040 in the CR6 handheld unit. Capacity is matched to the original specification at 88.8Wh.

  • CR6 platform fit: The CR6 uses a fixed 24V Ni-MH pack with a connector and BMS handshake tied to the 170-2040 specification. This replacement meets the same voltage rail and cell count so the device's charge controller recognises it without flagging a fault.
  • Bench tested on actual hardware: We cycled this pack through charge and full-load discharge on a simulated CR6 load profile. The BMS completed cell balancing without cutoff, and voltage held stable across the discharge curve through the first three cycles.
  • Post-swap self-test protocol: After installing this battery, let the CR6 complete its power-on self-test without interrupting the sequence. The device runs a BMS verification at startup — cutting power mid-sequence triggers a false battery fault that does not clear until a full reboot.

Why the CR6 BMS rejects a new cell on first boot

The CR6 charge controller stores the previous cell's discharge signature. A fresh Ni-MH pack presents a different internal resistance profile, which can cause the BMS to flag the cell as mismatched on the first power-on. This is not a fault in the replacement cell — it is the controller comparing against stored values. Running one full charge-discharge cycle gives the BMS enough data to update its reference and accept the new pack. After that cycle, the alarm clears and does not return.

Charge indicator stalls below 100% on first charge

On the first charge, the CR6's charge IC applies a conservative current limit when it does not recognise a seasoned cell profile. The indicator may stop climbing at 85–95% and hold there. This is the IC capping input voltage as a precaution, not a failed charge. Let the charge cycle complete fully without removing the battery early. After the first full cycle, the IC recalibrates and subsequent charges reach 100% normally — confirmed at 28.8V open-circuit at full charge.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Biosealer
Fit Model
CR6
Part Number
170-2040

Specifications

Battery typeNi-MH
Voltage24V
Capacity3700mAh
Wh88.8Wh
Dimensions168.30 x 69.10 x 34.00mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.