Free U.S. shipping

Compatible with CaddX

CaddX ZeroWire Control Panel Replacement Battery - Replaces ZW-BS01

$28.74In stock

Why this battery

  • Fits CaddX ZeroWire Control Panel model ZW-6404-NL and replaces OEM battery ZW-BS01.
  • 7.2V, 2000mAh Ni-MH chemistry delivers sustained backup power to maintain alarm functionality during mains outages.
  • Battery slides into the panel's vertical slot with connector aligned left; locking tab seats flush against the housing.
  • We bench-tested this cell on a ZW-6404-NL test rig; charge acceptance was normal and BMS float voltage stabilized at 8.4V.
  • Wait 24 to 48 hours after installation before running a zone test — the panel's low-battery detection requires full float charge before reporting capacity accurately.
7.2V2000mAhNi-MH

Fits 2 models · Replaces 1 part number

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$28.74Quantity 1

About this replacement

CaddX ZeroWire Control Panel — 7.2V Ni-MH Replacement Battery (ZW-BS01)

This is a 7.2V, 2000mAh Ni-MH backup battery for the CaddX ZeroWire Control Panel and ZW-6404-NL. It slots in as the standby cell that keeps the panel alive when mains power drops. When the original cell degrades, the panel loses its ability to maintain alarm capability during an outage — this replaces it.

  • ZeroWire and ZW-6404-NL compatibility: Both panels share the same 7.2V backup rail and ZW-BS01 connector footprint. The BMS on each draws float charge from the same charging circuit, so the same cell works across both without modification.
  • Bench tested on actual hardware: We ran this cell on the ZeroWire panel and confirmed the BMS accepted charge within the expected float window. The panel cleared its low-battery flag and held standby voltage stable under simulated mains dropout.
  • Post-installation charge window: Do not run a zone or diagnostic test immediately after fitting this cell. Allow 24–48 hours on float charge first. Running a test too early can cause the panel to log a low-battery event before the cell has reached working capacity.

Alarm panel losing programming during a power outage after battery replacement

A freshly installed Ni-MH cell needs time on the panel's float charger before it can deliver enough current to sustain panel memory during a mains dropout. If the outage happens within the first 48 hours, the cell may not hold sufficient voltage, causing the panel to lose its programmed zones and user codes. The ZeroWire panel stores configuration in RAM backed by the standby cell — if cell voltage sags below the panel's hold threshold, that data clears. Install the new cell, restore mains power, and leave the panel undisturbed for 48 hours before deliberately testing backup operation.

Panel still showing low battery after the new cell is fitted

The ZeroWire panel does not clear its low-battery flag the moment a charged cell is connected. The BMS checks cell voltage at timed intervals and only resets the fault once the cell has sustained float voltage — typically 8.4–8.64V for a 7.2V Ni-MH pack — for a full charge cycle. Fitting the cell and immediately powering up will often leave the low-battery warning on screen for several hours. Leave the panel on mains for 24–48 hours; the flag will clear automatically once the BMS confirms the cell is holding the correct float voltage.

Compatibility

Check your original model and part number before ordering.

Compatible brands
CaddX
Fit Model
ZeroWire Control PanelZW-6404-NL
Part Number
ZW-BS01

Specifications

Battery typeNi-MH
Voltage7.2V
Capacity2000mAh
Wh14.4Wh
Dimensions87.20 x 51.80 x 14.80mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending