$50.98In stock

Why this battery

  • Fits Carejoy V7, H8, and V8 handheld ultrasound scanners; replaces OEM battery SNLB-264.
  • This 11.1V, 2500mAh Li-Polymer cell powers extended diagnostic sessions without device shutdown mid-procedure.
  • Connector seats flush into the battery slot with a positive locking tab; orientation marked on housing.
  • We cycled the pack on a V7 unit; BMS initialized cleanly and held voltage under sustained ultrasound transducer load.
  • Allow the device to complete its power-on self-test cycle without interruption after installation — ultrasound scanners run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until full reboot.
11.1V2500mAhLi-Polymer

Fits 4 models · Replaces 1 part number

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$50.98Quantity 1

About this replacement

Carejoy V7 / H8 Handheld Portable Ultrasound Scanner — 11.1V Li-Polymer Replacement Battery (SNLB-264)

This is an 11.1V, 2500mAh Li-Polymer replacement battery for the Carejoy V7, H8, and V8 handheld portable ultrasound scanners. It matches the SNLB-264 OEM part number and fits the same battery bay without modification. Capacity is rated at 27.75Wh, consistent with the original cell specification.

  • V7, H8, and V8 platform fit: These three models share a common battery bay geometry, connector pinout, and BMS handshake protocol. The shared power architecture means one cell SKU covers the full scanner family without adapters or wiring changes.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on a medical-grade load tester. The BMS negotiation completed correctly, charge termination triggered at the expected voltage, and protection circuits responded normally to overload simulation.
  • Post-installation self-test protocol: After fitting this battery, allow the scanner to complete its full power-on self-test without interruption. Medical ultrasound devices run a BMS verification routine at startup — cutting power during this sequence logs a false battery fault that persists until the next full reboot cycle.

Device not completing boot sequence on new battery

Handheld ultrasound scanners run a power integrity check before completing boot. A new Li-Polymer cell can sit just below the BMS pass threshold if it has partially self-discharged during storage. The device reads this as a power fault and halts the sequence before reaching the main interface. Charge the battery fully before the first boot attempt — the scanner's charge IC may apply a conservative pre-charge trickle to new cells, so allow at least a full uninterrupted charge cycle before drawing conclusions about battery condition.

Low battery alarm triggering immediately after a confirmed full charge

This alarm occurs when the BMS compares the new cell's discharge curve against the OEM chemistry profile stored in firmware. A fresh cell's internal resistance profile differs slightly from a conditioned one, and the scanner interprets the early voltage response as low capacity. This is not a faulty battery — it is the BMS calibration window. Run one complete charge-to-discharge-to-full-charge cycle before clinical use, and the firmware will update its reference curve. After that cycle, the alarm threshold aligns correctly and the false trigger stops.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Carejoy
Fit Model
V7H8Handheld Portable Ultrasound Scanner H8Handheld Portable Ultrasound Scanner V8
Part Number
SNLB-264

Specifications

Battery typeLi-Polymer
Voltage11.1V
Capacity2500mAh
Wh27.75Wh
Dimensions89.60 x 84.90 x 18.50mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending