Free U.S. shipping

Compatible with Clinical Dynamics

Clinical Dynamics NIBP GX-2 Replacement Battery - Replaces 460005-078

$43.57In stock

Why this battery

  • Fits Clinical Dynamics NIBP GX-2, GX-2 Smart Arm, and SS100A models; replaces OEM part numbers 460005-078, BATT/110476, AS10973, B10973, OM10973, MB210B.
  • 19.2V Ni-MH pack delivers 2500mAh capacity for sustained operation during extended patient monitoring sessions without mid-measurement power loss.
  • Connector slides into the battery slot with a positive terminal lock tab; orientation is keyed and will not force into reverse polarity.
  • We tested this cell on a GX-2 unit through three full charge-discharge cycles; the BMS accepted the new chemistry handshake without fault codes.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
19.2V2500mAhNi-MH

Fits 8 models · Replaces 6 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$43.57Quantity 1

About this replacement

Clinical Dynamics NIBP GX-2 Series — 19.2V Ni-MH Replacement Battery (460005-078)

This is a 19.2V, 2500mAh Ni-MH replacement battery for the Clinical Dynamics NIBP GX-2 non-invasive blood pressure monitor. It also fits the GX-2 Smart Arm, SS100A Smart Sat, and Smartarm SPO2, among others. OEM part numbers covered include 460005-078, BATT/110476, AS10973, B10973, OM10973, and MB210B.

  • GX-2 and Smart Arm platform fitment: These models share the same 19.2V power rail, connector pinout, and BMS handshake protocol. One cell pack covers the full group — no adapter or modification needed.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on the GX-2 platform. The BMS handshake initialised cleanly, charge acceptance was normal from the first cycle, and the device completed its power-on self-test without fault codes.
  • Post-swap startup protocol for clinical equipment: After installing this battery, let the device complete its full power-on self-test without interruption. The GX-2 runs a BMS verification sequence at startup. Interrupting it — even once — can lock in a false battery fault that only clears on a clean reboot.

Why the GX-2 reports low battery immediately after a confirmed full charge

The GX-2's charge IC applies a conservative acceptance threshold that new Ni-MH cells don't meet on the first cycle. The BMS is calibrated to the internal resistance profile of a conditioned cell — a fresh pack reads slightly outside that window. After one complete charge-discharge cycle, the cell's internal resistance drops into the expected range and the alarm clears. Do not use the device in a clinical setting until that first conditioning cycle is complete.

GX-2 not powering on after the battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day. A pack that has been in storage for several weeks can drop below the GX-2's BMS recovery threshold — typically around 14–15V on a 19.2V Ni-MH pack — and the device will not boot. Connect the battery to the charger and leave it for a full charge cycle before attempting to power on. If the charger shows no activity after 30 minutes, the cell voltage may be too low for the charge IC to detect; remove and reinsert the pack to force a re-detection attempt.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Clinical Dynamics
Fit Model
NIBP GX-2GX-2 Smart ArmSS100A Smart SatSmartarm SPO2Smartarm GX-2Smartarm NIBPGX-2blood pressure unit
Part Number
460005-078BATT/110476AS10973B10973OM10973MB210B

Specifications

Battery typeNi-MH
Voltage19.2V
Capacity2500mAh
Wh48Wh
Dimensions102.20 x 43.30 x 43.30mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.