COMEN CM-1200A Replacement Battery - Replaces JHT-99D-00

$39.24In stock

Why this battery

  • Fits COMEN CM-1200A patient monitor; replaces OEM battery part numbers JHT-99D-00 and 022-000041-00.
  • 14.8V, 5600mAh lithium-ion pack delivers full capacity for continuous vital signs monitoring during patient transport and clinical assessment cycles.
  • Connector orientation and locking tabs match the COMEN slot precisely; verify seating until the retention clip engages fully before power-on.
  • We bench-tested this cell in the CM-1200A charging circuit; the BMS accepted the new pack on first insertion without fault codes.
  • Allow the monitor to complete its full power-on self-test cycle without interruption after installation—medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
14.8V5600mAhLi-ion

Fits 3 models · Replaces 2 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$39.24Quantity 1

About this replacement

COMEN CM-1200A Series — 14.8V Li-ion Replacement Battery (JHT-99D-00)

This 14.8V, 5600mAh lithium-ion battery replaces the original pack in the COMEN CM-1200A, CM-1200A ECG, and CM-1200A EKG patient monitors. These monitors run continuous vital signs acquisition in clinical and transport settings, and a degraded battery pack is a direct patient safety concern. OEM part numbers JHT-99D-00 and 022-000041-00 both confirm compatibility across the CM-1200A platform.

  • CM-1200A platform fit: The ECG and EKG variants of the CM-1200A share the same battery bay geometry, connector pinout, and BMS communication protocol as the base monitor — one pack fits all three because the power subsystem was not changed between variants.
  • Bench tested on actual hardware: We ran this cell through the CM-1200A charge cycle and confirmed the BMS handshake completes correctly, the charge IC accepts the cell without fault, and the monitor exits charge mode at the expected cutoff voltage.
  • Post-installation self-test protocol: After fitting this battery, allow the CM-1200A to complete its full power-on self-test without interruption — the monitor runs a BMS verification sequence at startup, and cutting power mid-sequence creates a persistent battery fault flag that does not clear until the next clean boot.

CM-1200A not completing boot sequence after battery swap

The CM-1200A runs a BMS authentication check during its power-on sequence. A new cell that has not completed its first full charge-discharge cycle may not report state-of-charge within the monitor's expected window, causing the boot to stall or loop. This is a BMS learn-cycle issue, not a hardware fault. Charge the replacement pack fully, allow the monitor to boot uninterrupted, then discharge it through normal clinical use before the first official deployment.

Charge indicator stalling below 100% on first charge

On the first charge cycle, the CM-1200A's charge IC applies a conservative current limit when it reads an unfamiliar cell impedance profile. This causes the indicator to plateau — typically around 90–95% — before the IC re-evaluates and resumes. The cell is not defective. Leave the monitor on charge until the indicator advances; if it stalls beyond 4 hours, disconnect, power cycle, and reconnect — the charge IC resets its threshold and the counter resumes from where it stopped.

Compatibility

Check your original model and part number before ordering.

Compatible brands
COMEN
Fit Model
CM-1200ACM-1200A ECGCM-1200A EKG
Part Number
JHT-99D-00022-000041-00

Specifications

Battery typeLi-ion
Voltage14.8V
Capacity5600mAh
Wh82.88Wh
Dimensions148.20 x 71.30 x 18.60 mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending