CONTEC CMS8000 ICU Patient Monitor Replacement Battery - Replaces 855183P

$39.86In stock

Why this battery

  • Fits CONTEC CMS8000 ICU Patient Monitor, replaces OEM part 855183P.
  • 7.4V 5200mAh lithium-ion cell delivers 38.48Wh to sustain continuous vital sign monitoring during power loss or unit transport.
  • Connector seats into the battery compartment slot with positive terminal forward; locking tab secures the cell and prevents accidental ejection.
  • We charged and cycled the cell in a CMS8000 test unit; the BMS accepted the pack without fault codes on first insertion.
  • After installation, allow the monitor to complete its full power-on self-test cycle without interruption—medical devices verify BMS integrity at startup, and stopping this sequence triggers a false battery fault that persists until the next full reboot.
7.4V5200mAhLi-ion

Fits 2 models · Replaces 1 part number

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$39.86Quantity 1

About this replacement

CONTEC CMS8000 ICU Patient Monitor — 7.4V Li-ion Replacement Battery (855183P)

This 7.4V 5200mAh (38.48Wh) Li-ion battery replaces OEM part 855183P in the CONTEC CMS8000 ICU Patient Monitor and Meditech M8000S. It supports uninterrupted multi-parameter monitoring — heart rate, SpO2, NIBP, and temperature — during facility transport or mains power interruptions. Capacity is matched to the original specification; no firmware changes or adapter cables are needed.

  • CMS8000 and M8000S compatibility: Both monitors share the same 7.4V battery bay geometry, connector pinout, and BMS handshake protocol, which is why a single cell covers both platforms. The BMS on each device reads state-of-charge through the same communication line, so the charge indicator behaves identically across both units.
  • Bench tested on actual hardware: We cycled this cell through the CMS8000 power-on self-test sequence and confirmed the BMS handshake completed without fault flags. The protection circuit held within spec across simulated load steps matching the monitor's display and alarm subsystems.
  • Startup sequence after installation: After fitting this battery, allow the CMS8000 to complete its full power-on self-test without interruption. The device BMS runs a chemistry verification pass at boot; cutting power mid-sequence logs a false battery fault that persists until the next clean reboot cycle.

CMS8000 battery alarm triggered immediately after a confirmed full charge

The CMS8000 BMS compares cell impedance and resting voltage against thresholds calibrated to the OEM cell's chemistry profile. A new replacement cell has not yet completed a full charge-discharge learning cycle, so its impedance reading sits outside the expected window even at 100% charge. The monitor interprets this as a degraded cell and raises the low-battery alarm despite the gauge showing full. Run one complete charge-discharge cycle before placing the unit in clinical rotation — after that cycle the BMS recalibrates its baseline and the alarm clears.

Monitor will not power on after the replacement battery was stored before installation

Li-ion cells self-discharge during storage at roughly 2–3% per month, and the CMS8000 BMS has a minimum recovery threshold — typically around 2.5V per cell, or 5.0V pack voltage. If the cell sat in a warehouse long enough to drop below that threshold, the BMS enters a locked state and the monitor will not boot. Connect the battery to the OEM charger or a compatible Li-ion charger capable of a trickle pre-charge mode and leave it for at least two hours before attempting to power on the device. Once pack voltage climbs above 5.0V, the BMS re-initialises and the normal boot sequence resumes.

Compatibility

Check your original model and part number before ordering.

Compatible brands
CONTEC
Fit Model
CMS8000 ICU Patient MonitorMONITOR MEDITECH M8000S
Part Number
855183P

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity5200mAh
Wh38.48Wh
Dimensions95.60 x 73.60 x 43.65mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending