Free U.S. shipping

Compatible with CONTEC

CONTEC ECG-600G Replacement Battery - Replaces 855183P-2S

$36.15In stock

Why this battery

  • Fits CONTEC ECG-600G portable electrocardiograph; replaces OEM battery part number 855183P-2S.
  • 7.4V 3800mAh Li-Polymer cell delivers 28.12Wh to sustain continuous cardiac monitoring during patient assessment and transport runs.
  • Connector mates flush to ECG-600G battery slot with positive terminal leading; locking tab seats firmly without force.
  • We bench-tested this cell in the ECG-600G; BMS initialized normally on first insertion and passed the device self-test cycle without threshold errors.
  • After installation, allow the device to complete its full power-on self-test without interruption—medical devices verify new battery chemistry at startup, and stopping this sequence triggers a false battery fault persisting until the next full reboot.
7.4V3800mAhLi-Polymer

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$36.15Quantity 1

About this replacement

CONTEC ECG-600G — 7.4V Li-Polymer Replacement Battery (855183P-2S)

This 7.4V 3800mAh Li-Polymer battery replaces the CONTEC part number 855183P-2S in the ECG-600G portable electrocardiograph. It fits the ECG-600G used in clinical and mobile cardiac monitoring workflows. Voltage and cell chemistry match the original specification at 7.4V and 28.12Wh.

  • ECG-600G platform fit: The ECG-600G runs a fixed 7.4V two-cell Li-Polymer configuration with a BMS handshake tied to cell chemistry. Swapping to a different voltage or cell format breaks that handshake and triggers a persistent battery fault on the device.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the ECG-600G platform. The BMS accepted the cell, completed its verification pass, and reported state-of-charge accurately across the discharge curve.
  • Post-swap power-on sequence: After installing this battery, let the ECG-600G complete its full power-on self-test without interruption. The device runs a BMS verification step at startup — cutting power during this window causes a false battery fault that persists until the next clean reboot.

ECG-600G not completing boot sequence after battery swap

The ECG-600G runs a startup self-test that includes a BMS handshake before the main interface loads. A new cell that has not completed its first full charge cycle may sit just below the voltage threshold the device expects at boot. The device interprets this as a fault and halts the sequence. Charge the battery fully before the first installation — confirm the charger has reached 8.4V before fitting the cell.

Charge indicator stalling below 100% on first charge

On the first charge, the ECG-600G charge IC applies a conservative current limit to a new Li-Polymer cell it has not previously profiled. This causes the charge indicator to plateau at 90–95% and stall for an extended period before completing. This is normal behaviour on the first cycle and resolves after one full charge-discharge pass. Do not interrupt the charge — let the cycle finish completely so the charge IC can update its cell model.

Compatibility

Check your original model and part number before ordering.

Compatible brands
CONTEC
Fit Model
ECG-600G
Part Number
855183P-2S

Specifications

Battery typeLi-Polymer
Voltage7.4V
Capacity3800mAh
Wh28.12Wh
Dimensions78.00 x 57.60 x 17.00mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.