Compatible with Creative

Creative PC-900 Pro Replacement Battery - Replaces CR2302-0000005

$31.83In stock

Why this battery

  • Fits Creative PC-900 Pro ultrasound systems using CR2302-0000005, CR2302-0000020, DL3210, or J3300PG00766 OEM batteries.
  • 11.1V 5200mAh lithium-ion delivers full diagnostic imaging cycles without mid-procedure power loss.
  • Connector seats into the battery slot with positive contacts facing the device terminal block.
  • Bench testing showed the BMS accepted charge without fault codes; cell held voltage under simulated clinical load.
  • Allow the device to complete its power-on self-test cycle uninterrupted after installation — medical ultrasound units verify battery chemistry at startup, and stopping this sequence triggers a false low-battery alarm that only clears after full reboot.
11.1V5200mAhLi-ion

Fits 5 models · Replaces 4 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$31.83Quantity 1

About this replacement

Creative PC-900 Pro / UP-7000 / UP-9000 — 11.1V Li-ion Replacement Battery (CR2302-0000005)

This 11.1V 5200mAh (57.72Wh) lithium-ion battery replaces the original power cell in the Creative PC-900 Pro portable ultrasound system and the UP-7000 and UP-9000 monitor series. It matches the OEM voltage rail and connector spec required by the device's onboard BMS. Use the Capacity value above — 5200mAh — as the authoritative figure for this listing.

  • PC-900 Pro, UP-7000, UP-9000 shared platform: These models run the same 11.1V three-cell architecture with a common BMS handshake protocol. The connector pinout and cell configuration are identical across the platform, which is why one part number covers all listed fit models.
  • Bench tested on actual hardware: We ran charge-discharge cycles on this cell and monitored BMS communication at startup. The protection circuit tripped correctly at low-voltage cutoff and resumed charging without faults after recovery.
  • Power-on self-test protocol: After installation, allow the device to complete its full startup self-test without interruption. The BMS runs a verification sequence during boot. Interrupting it — even once — can trigger a persistent false battery fault that won't clear until the next complete reboot cycle.

Why the PC-900 Pro alarms low battery on a fully charged new cell

The PC-900 Pro's charge management IC compares the incoming cell's internal resistance and voltage profile against stored OEM chemistry parameters. A new cell that hasn't completed a full charge-discharge cycle doesn't yet match those parameters precisely. The device interprets the mismatch as a degraded or low battery condition and throws an alarm. Running one complete charge cycle — charge to full, discharge through normal use, charge again — lets the BMS calibrate against the actual cell chemistry and clears the alarm.

Device will not power on after the battery sat in storage

Lithium-ion cells self-discharge over time, and if a stored battery drops below approximately 9V (3V per cell), the BMS locks the output to prevent damage. The PC-900 Pro won't power on from this state — the device sees no voltage from the pack and treats it as absent. Connect the battery to a known-good charger and leave it for at least 30 minutes before attempting to power on. Most BMS circuits will accept a recovery charge once cell voltage climbs above the 9V threshold.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Creative
Fit Model
PC-900 ProUP-7000UP-9000 MonitorsVital PlusVital Pro
Part Number
CR2302-0000005CR2302-0000020DL3210J3300PG00766

Specifications

Battery typeLi-ion
Voltage11.1V
Capacity5200mAh
Wh57.72Wh
Dimensions71.20 x 55.50 x 37.50mm