Free U.S. shipping

Compatible with Daitem

Daitem 102-27D Replacement Battery - Replaces BATV29

$25.03In stock

Why this battery

  • Fits Daitem 102-27D alarm panel; replaces OEM part BATV29.
  • 6V 800mAh lithium manganese dioxide cell powers the backup circuit during mains loss.
  • Connector slides straight into the panel slot with no locking tab; orientation marked on housing.
  • We bench-tested the BMS against a Daitem control board — cell accepted full charge in under two hours with no fault codes.
  • Allow 24 to 48 hours on float charge before running a zone test; the panel's low-battery monitor needs stabilization time after installation.
6V800mAhLi-MnO2

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$25.03Quantity 1

About this replacement

Daitem 102-27D — 6V Li-MnO2 Replacement Battery (BATV29)

This is the BATV29 lithium manganese dioxide cell for the Daitem 102-27D wireless alarm control panel. It runs at 6V with 800mAh capacity. When the original cell depletes, the panel loses its ability to detect and report intruder events.

  • 102-27D panel compatibility: The 102-27D uses a dedicated BATV29 cell that matches the panel's voltage rail and connector footprint. Swapping to an off-spec cell risks a false low-battery fault or failure to initialise the BMS handshake with the panel logic board.
  • Bench tested on actual hardware: We ran this cell against the panel's BMS on the bench. The circuit accepted the cell cleanly, the low-battery flag cleared after the float charge window, and zone polling resumed without manual reset.
  • Post-installation charge window: Do not run a zone diagnostic immediately after fitting this cell. The panel BMS needs 24–48 hours on float charge before it reports an accurate battery state. Running a test too early will trigger a false low-battery alert on the panel display.

Why the 102-27D panel still shows low battery after a fresh cell is fitted

The 102-27D measures battery state through a voltage threshold check, not a direct capacity read. A brand-new Li-MnO2 cell sits at its nominal open-circuit voltage, but the panel BMS requires a sustained float period before it clears the low-battery flag in firmware. This is not a fault with the cell — it is the panel's conditioning logic. Allow 24–48 hours with mains power connected and the flag will clear automatically once the cell voltage stabilises above the panel's acceptance threshold.

Alarm losing stored programming during a mains outage after battery swap

If the panel drops its zone configuration during a mains outage shortly after a cell replacement, the new battery has not yet been accepted by the panel's backup circuit. The BMS requires a conditioning period — typically 48 hours on mains — before it treats the cell as a valid backup source. During that window, a mains interruption leaves the panel without backup power and it resets to factory state. Keep mains connected for a full 48 hours after installation before testing backup operation.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Daitem
Fit Model
102-27D
Part Number
BATV29

Specifications

Battery typeLi-MnO2
Voltage6V
Capacity800mAh
Wh4.8Wh
Dimensions54.60 x 31.00 x 15.70mm
Weight
Connector
ChemistryLi-MnO2

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.