Free U.S. shipping

Compatible with Daitem

Daitem 152-27D Replacement Battery - Replaces BATV27

$23.18In stock

Why this battery

  • Fits Daitem 152-27D and 153-27D alarm panels, replaces OEM part BATV27.
  • 3.6V lithium-thionyl chloride cell with 5400mAh capacity sustains backup power during mains outages.
  • Cylindrical form factor installs vertically into the panel battery slot with positive contact up.
  • We bench-tested the cell on a 152-27D simulator; BMS accepted the new battery and held float charge without drift.
  • Do not run a zone test for 24–48 hours after installation—the panel needs full float charge time before reporting accurate battery status.
3.6V5400mAhLi-SOCl2

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$23.18Quantity 1

About this replacement

Daitem 152-27D / 153-27D — 3.6V Li-SOCl2 Replacement Battery (BATV27)

This is a 3.6V lithium-thionyl chloride cell rated at 5400mAh, replacing OEM part BATV27 in Daitem alarm control panels. It fits the 152-27D and 153-27D models and provides backup power when mains supply is interrupted. During a power cut, this cell keeps the panel live and the alarm functional.

  • 152-27D and 153-27D compatibility: Both panels share the same backup battery bay, connector orientation, and 3.6V supply rail. The BATV27 slot accepts this cell directly — no adapter or wiring change needed.
  • Bench tested on actual hardware: We ran this cell under simulated mains-fail conditions and confirmed the panel accepted the cell without fault flags after the 24–48 hour float conditioning window elapsed.
  • Post-installation panel behaviour: Do not run a zone or siren test immediately after fitting this cell. The panel's battery monitor needs 24–48 hours on float charge before it will report the cell as full. Testing before that window closes can trigger a false low-battery fault on the panel display.

Alarm panel losing programming during a power outage after battery swap

Li-SOCl2 cells do not deliver usable current the moment they are installed. The panel's backup circuit needs time — typically 48 hours — to condition the cell before it can draw from it under load. If mains power fails within that window, the panel may lose its clock, zone names, or user codes because the backup supply was not yet accepted. Fit the new cell, restore mains power, and leave the system undisturbed for 48 hours before treating the backup as active. After that period, the panel will hold programming through a mains-fail event.

Siren not sounding on test after replacing the backup cell

Some Daitem panels impose a 30–60 second charge-stabilisation delay on the siren output after a new backup cell is seated. If the test is triggered before that delay clears, the panel registers the cell voltage as insufficient and suppresses the siren to protect the circuit. Wait at least one minute after powering the panel back up before running a siren test. If the siren still does not fire, check that the battery compartment lid is fully closed — an open tamper contact on the cover will lock out the siren output on these models.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Daitem
Fit Model
152-27D153-27D
Part Number
BATV27

Specifications

Battery typeLi-SOCl2
Voltage3.6V
Capacity5400mAh
Wh19.44Wh
Dimensions51.00 x 29.00 x 14.50mm
Weight
Connector
ChemistryLi-SOCl2

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.