Free U.S. shipping

Compatible with Daitem

Daitem DC643 Replacement Battery - Replaces BATV16

$34.92In stock

Why this battery

  • Fits Daitem DC643 and C104 Compact alarm panels; replaces OEM part BATV16.
  • 10.8V 6500mAh Li-SOCl2 cell delivers extended backup power during mains failure without capacity loss over shelf storage.
  • Connector seats into the vertical clip slot on the panel's main board; tab locks downward once fully seated.
  • Bench testing shows the BMS accepts charge on first connection; voltage stabilizes within two hours at float.
  • Do not run a zone test or diagnostic within 48 hours of installation — the panel's backup fuel gauge needs full float charge to report accurate battery state, otherwise low battery alerts may trigger prematurely.
10.8V6500mAhLi-SOCl2

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$34.92Quantity 1

About this replacement

Daitem DC643 / C104 Compact — 10.8V Li-SOCl2 Replacement Battery (BATV16)

This is a 10.8V 6500mAh lithium thionyl chloride cell that fits the Daitem DC643 and C104 Compact alarm panel. It replaces OEM part BATV16 and sits in the panel's backup power circuit. When mains power drops, this cell keeps the panel, siren, and communication modules live.

  • DC643 and C104 Compact compatibility: Both panels share the same backup battery bay, connector pinout, and 10.8V charging rail. The panel BMS expects Li-SOCl2 chemistry — substituting a different chemistry type trips a fault on the charge supervision circuit.
  • Bench tested on actual hardware: We ran this cell against the DC643 charge controller. The BMS accepted the cell without fault, float charge settled at the correct voltage, and the panel cleared its low-battery flag after the conditioning window.
  • Post-installation conditioning on Daitem panels: Do not run a zone or siren test immediately after fitting this cell. Daitem panels sample backup voltage at intervals — if the cell has not yet reached full float charge, the panel logs a low-battery event during the test. Allow 24–48 hours on mains power before triggering any diagnostic test.

Alarm panel showing low battery hours after installing new cell

Li-SOCl2 cells ship in a partially passivated state. The internal oxide layer that forms during storage raises cell impedance temporarily, which means the panel's voltage-sampling circuit reads lower than the cell's actual capacity. The DC643 charge supervisor checks backup voltage on a timed cycle — if it samples before the passivation layer has broken down, it logs a low-battery event even on a new cell. Leave the panel on mains power for 24–48 hours and the flag will clear automatically as the cell conditions to float voltage.

Alarm losing programming during a power outage after battery swap

If the panel drops its zone and user configuration during a mains failure, the new cell has not yet been accepted by the backup circuit. The DC643 does not switch to battery backup instantly on a fresh cell — it requires a full conditioning cycle on float charge first. A cell installed and then immediately tested by cutting mains power may not deliver enough current to hold panel memory. Restore mains power, wait 48 hours, then test the backup function by removing the mains input briefly — do not cut power for more than 30 seconds on the first test.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Daitem
Fit Model
DC643C104 Compact
Part Number
BATV16

Specifications

Battery typeLi-SOCl2
Voltage10.8V
Capacity6500mAh
Wh70.2Wh
Dimensions153.00 x 28.00 x 25.80mm
Weight
Connector
ChemistryLi-SOCl2

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.