Compatible with Edan

Edan EPM5 Replacement Battery - Replaces 01.21.064380

$28.12In stock

Why this battery

  • Fits Edan EPM5, EPM7, EPM8 patient monitors; replaces OEM part 01.21.064380 and ID995.
  • 10.8V, 2600mAh lithium-ion delivers continuous power for portable vital signs monitoring without runtime interruption.
  • Connector type matches OEM specification; slides into battery slot with positive contact alignment toward device housing.
  • We bench-tested this cell in EPM5 startup mode; BMS handshake completed cleanly without fault codes or boot delays.
  • After installation, allow the device to complete its full power-on self-test cycle without interruption — medical device firmware verifies the new cell during startup, and stopping this sequence triggers a false battery fault that persists until next full reboot.
10.8V2600mAhLi-ion

Fits 7 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$28.12Quantity 1

About this replacement

Edan EPM5 / EPM7 / EPM8 Series — 10.8V Li-ion Replacement Battery (01.21.064380)

This is a 10.8V, 2600mAh Li-ion battery for the Edan EPM5, EPM7, and EPM8 portable patient monitors and the SE-1203 series. It replaces OEM part numbers 01.21.064380 and ID995. These monitors are used in clinical transport and ward settings where continuous vital signs display depends entirely on battery integrity.

  • EPM5, EPM7, EPM8, and SE-1203 compatibility: These models share a common 10.8V three-cell Li-ion architecture with the same physical connector and BMS communication protocol. One cell pack covers all of them without modification.
  • Bench tested on actual hardware: We cycled this battery through the EPM5 power-on self-test and monitored BMS handshake response. The charge IC accepted the cell without faulting, and the monitor cleared its battery status flag cleanly after one full charge-discharge cycle.
  • Post-swap self-test protocol: After installing this battery, let the monitor complete its full power-on self-test without interruption. The EPM series runs BMS verification at every startup — cutting power during this sequence latches a false battery fault that will persist until the next clean reboot.

Why the EPM monitor alarms low battery immediately after a confirmed full charge

The EPM series BMS stores a charge threshold profile calibrated to the OEM cell's internal resistance signature. A new replacement cell presents a slightly different impedance curve on the first cycle, which the BMS reads as below its pass threshold and triggers the alarm. This is not a cell fault. Run one complete charge-discharge cycle — charge to full, allow normal monitor operation until the low battery warning appears naturally, then recharge fully. After that cycle, the BMS recalibrates its threshold map and the false alarm clears.

Monitor will not power on after the replacement cell sat in storage

Li-ion cells self-discharge at roughly 2–3% per month. A battery stored for several months before installation can drop below the EPM's BMS recovery threshold — typically around 9.0V for a 10.8V three-cell pack — which causes the BMS to block output entirely as a protection measure. Connect the battery to the Edan charger and leave it for at least 30 minutes before attempting to power the monitor. Most BMS controllers on this platform include a trickle pre-charge mode that recovers cells down to approximately 8.5V before enabling full charge current.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Edan
Fit Model
EPM5EPM7EPM8SE-1203X10 Patient MonitorX12 Patient MonitorX8 Patient Monitor
Part Number
01.21.064380ID995

Specifications

Battery typeLi-ion
Voltage10.8V
Capacity2600mAh
Wh28.08Wh
Dimensions68.00 x 55.00 x 19.00mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning