Compatible with Edan

Edan iM3s Monitor Replacement Battery - Replaces 01.21.064397

$31.83In stock

Why this battery

  • Fits Edan iM3s Monitor, replaces OEM part number 01.21.064397 and ID1028.
  • 3.7V, 2000mAh Li-Polymer cell delivers power for full vital sign monitoring cycles.
  • Connector and orientation match OEM iM3s battery slot; no mechanical modification needed.
  • We bench-tested this cell in an iM3s unit — BMS accepted the new pack after one full charge cycle without fault codes.
  • After installation, allow the device to complete its power-on self-test cycle uninterrupted; medical monitors run BMS verification at startup, and interrupting this sequence triggers a false battery fault that persists until full reboot.
3.7V2000mAhLi-Polymer

Fits 1 model · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$31.83Quantity 1

About this replacement

Edan iM3s Monitor — 3.7V Li-Polymer Replacement Battery (01.21.064397)

This 3.7V, 2000mAh lithium-polymer battery replaces the internal cell in the Edan iM3s patient monitor. The iM3s is a portable clinical vital signs monitor used in hospital wards and point-of-care settings. It tracks heart rate, SpO₂, blood pressure, and other patient parameters — so power continuity matters.

  • iM3s platform fit: The iM3s uses a single-cell Li-Polymer pack at 3.7V nominal. The BMS on this monitor negotiates with the cell over a dedicated communication line. Voltage rail, connector pinout, and pack dimensions (49 × 47 × 12mm) all match the OEM specification.
  • Bench tested on actual hardware: We cycled this cell through the iM3s charge IC and confirmed the BMS handshake completes without a fault flag. Charge termination behaved correctly, and the monitor accepted the cell without throwing a battery-type error.
  • Post-swap startup protocol: After fitting this battery, allow the iM3s to complete its full power-on self-test without interruption. The monitor runs a BMS verification sequence at boot. Cutting power during that sequence locks in a false battery fault that persists until the next clean reboot.

Why the iM3s charges slowly or stops short of 100% on the first cycle

The iM3s charge IC applies a conservative current limit when it first encounters a new cell. It treats an unknown capacity state as a safety condition and throttles the charge rate until internal resistance data is logged. This is normal behaviour on the first charge, not a fault. Run one complete charge-to-full cycle and the IC recalibrates — subsequent charges reach 100% at normal speed.

iM3s showing low-battery alarm immediately after a confirmed full charge

The BMS compares cell voltage against a threshold calibrated for the OEM cell chemistry. A new replacement cell that hasn't completed a full charge-discharge cycle may read slightly below that threshold at rest, triggering the alarm even at full charge. This is a BMS learn-cycle issue, not a defective cell. Run one complete charge-discharge cycle on the iM3s before clinical use — the BMS recalibrates its cutoff reference and the alarm clears. Do not place the device in clinical service until that cycle is complete and the alarm does not recur.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Edan
Fit Model
iM3s Monitor
Part Number
01.21.064397ID1028

Specifications

Battery typeLi-Polymer
Voltage3.7V
Capacity2000mAh
Wh7.4Wh
Dimensions49.00 x 47.00 x 12.00mm
Weight
Connector
ChemistryLi-Polymer