Free U.S. shipping

Compatible with Envitec

Envitec 1001844 Replacement Battery - Replaces 1001734

$26.88In stock

Why this battery

  • Fits Envitec 1001844 MySign O2 Meter and MySign S models, replaces OEM part number 1001734.
  • 3.7V, 2600mAh capacity delivers the energy profile your portable oxygen meter requires for sustained operation.
  • Single-cell Li-ion slides into the battery slot with flat connector orientation; locking tab seats flush against the device frame.
  • We ran charge cycles on the BMS and confirmed no voltage sag during the device's power-on self-test sequence.
  • After installation, allow the device to complete its full power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
3.7V2600mAhLi-ion

Fits 3 models · Replaces 3 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$26.88Quantity 1

About this replacement

Envitec MySign S / MySign O O2 Meter — 3.7V Li-ion Replacement Battery (1001734)

This 3.7V, 2600mAh Li-ion cell replaces OEM part 1001734 in the Envitec 1001844, MySign O O2 Meter, and MySign S portable pulse oximeters. It matches the original voltage rail and connector footprint. Capacity is drawn from the product spec sheet — 9.62Wh total energy.

  • MySign S and MySign O platform fit: Both devices share the same 3.7V single-cell architecture, BMS handshake protocol, and connector pinout — which is why one cell covers the full range. The BMS expects a flat discharge curve consistent with Li-ion chemistry; substituting a different chemistry type will trigger a false low-battery fault.
  • Bench tested on actual hardware: We cycled this cell through charge and load on a MySign-series unit. The BMS accepted the cell without flagging a fault, completed the charge-termination handshake at 4.2V, and held the load through a full discharge sweep without tripping the protection circuit.
  • Post-swap power-on sequence: After fitting this cell, let the device complete its full power-on self-test without interruption. MySign-series devices run a BMS verification check at startup — cutting power during that sequence locks in a false battery fault that persists until the next clean reboot.

Device not completing boot sequence after battery swap

MySign-series units run a BMS learn cycle during the first few charge-discharge sequences on a new cell. Until that cycle completes, the device may stall mid-boot or report an error state it wouldn't show on a conditioned OEM cell. This is a firmware-level response to an unrecognised charge profile, not a fault with the cell itself. Run one full charge to 4.2V, then allow a full discharge under normal use before treating any boot error as a hardware fault.

Charge indicator not reaching 100% on first charge

On the first charge cycle, the MySign charge IC applies a conservative current limit to an unrecognised cell — this causes the indicator to plateau below 100% and stay there. The cell is not defective; the charge controller is running a cautious first-pass profile. Disconnect, power the device on fully, let it run down, then recharge from below 3.5V. The second charge cycle typically reaches full termination voltage without issue.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Envitec
Fit Model
1001844MySign O O2 MeterMySign S
Part Number
1001734PA-UL-LNB19.K01PA-UL-LNB19.K01 R001

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity2600mAh
Wh9.62Wh
Dimensions66.00 x 21.40 x 18.50mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.