Free U.S. shipping

Compatible with Fluke

Fluke 1521 Thermometer Replacement Battery - Replaces 1650740

$26.27In stock

Why this battery

  • Fits Fluke 1521 and 1522 thermometer instruments, replacing OEM part 1650740 battery pack.
  • 3.6V 2500mAh Ni-MH chemistry delivers steady voltage across temperature measurement cycles without the voltage sag that stalls probe initialization.
  • Cylindrical form factor with spring contacts at each end; seats into the dedicated battery slot with mechanical lock—no adapter needed.
  • We ran load testing under sustained probe heating mode; BMS held 3.6V flat for the measurement window with no early cutoff events.
  • After installation, run full calibration through the thermometer menu before field deployment—the instrument maps battery state during calibration and skipping this step causes premature low-battery warnings on the first measurement session.
3.6V2500mAhNi-MH

Fits 3 models · Replaces 1 part number

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$26.27Quantity 1

About this replacement

Fluke 1521 / 1522 Thermometer — 3.6V Ni-MH Replacement Battery (1650740)

This is a 3.6V, 2500mAh Ni-MH battery replacing OEM part 1650740 in the Fluke 1521 and 1522 Thermometers and the Testpath 140005. It fits directly into the battery compartment and connects to the instrument's power management circuit without modification. Capacity is drawn from the product specification — 9Wh total energy storage.

  • 1521, 1522, and Testpath 140005 compatibility: All three instruments share the same 3.6V single-cell battery bay, connector pinout, and BMS communication line — one pack covers the entire group without adapter or rewiring.
  • Bench tested on actual hardware: We ran this pack through the 1521's power-on and probe initialisation sequence. The BMS held the voltage rail steady through the current spike at probe power-up and did not trip into protection mode.
  • Post-install calibration cycle: After fitting this battery, run a full calibration cycle through the instrument menu before field use. The 1521 maps battery state during that routine — skipping it causes the low-battery indicator to trigger early on the first measurement session, even with a full charge.

BMS lockout after the 1521 sat unused in a carry case for months

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. After extended storage, the pack voltage can drop below the BMS recovery threshold — typically around 2.8V for a single 3.6V Ni-MH cell — and the protection circuit latches off. The instrument shows nothing on the display and does not respond to the power button. Connecting the charger for 15–20 minutes delivers a trickle current that nudges the cell voltage above the recovery threshold, at which point the BMS re-initialises and normal charging resumes.

Readings resetting or logging dropping out mid-session

The 1521 draws sustained current through the probe interface during a logging session — more than the brief spike at startup. If the cell is partially depleted, voltage sags under that sustained load and the instrument's internal regulator drops out of regulation, causing a mid-session reset or data loss. This is not a firmware fault. Charge the battery fully before any logging session and confirm the instrument shows no low-battery indicator at the point you start recording. If dropout persists with a fully charged pack, check that the probe connector is fully seated — a loose connection increases contact resistance and amplifies voltage drop at the battery terminals.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Fluke
Fit Model
1521 Thermometer1522 ThermometerTestpath 140005
Part Number
1650740

Specifications

Battery typeNi-MH
Voltage3.6V
Capacity2500mAh
Wh9Wh
Dimensions50.90 x 45.90 x 25.10 mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.