Free U.S. shipping

Compatible with Fluke

Fluke 700 Calibrator Replacement Battery - Replaces 116-066

$63.34In stock

Why this battery

  • Fits Fluke 700, 740, and 744 Calibrator models; replaces OEM part numbers 116-066, 668225, and BP7235.
  • 7.2V at 2500mAh supplies stable voltage during probe initialization and sustained measurement cycles on calibration instruments.
  • Connector slides straight into the battery slot with a single locking tab; polarity marked on the pack and housing.
  • We bench-tested this Ni-MH cell in a 700 Calibrator; BMS accepted the pack on first insertion and held voltage under 2-amp sensor load.
  • After installing, run one full calibration cycle through the instrument menu before field use — the device maps battery state during calibration and skips this cause premature low-battery warnings on the first measurement session.
7.2V2500mAhNi-MH

Fits 11 models · Replaces 3 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$63.34Quantity 1

About this replacement

Fluke 700 / 740 / 744 Calibrator Series — 7.2V Ni-MH Replacement Battery (BP7235)

This is a 7.2V 2500mAh Ni-MH replacement battery for the Fluke 700, 740, and 744 Calibrator series, along with the DSP-100 and compatible models. It slots into the battery compartment and powers the calibrator during portable field use and bench work. The OEM part numbers this pack replaces are 116-066, 668225, and BP7235.

  • Calibrator series compatibility: The 700, 740, and 744 Calibrators share the same battery bay dimensions, 7.2V rail, and connector pinout. One pack covers the full lineup without modification.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on calibrator-class load profiles. The BMS handled the initialisation current spike at instrument power-up without tripping, and held voltage steady under sustained sensor drive.
  • Post-install calibration cycle: After fitting this pack, run a full calibration cycle through the instrument menu before field deployment. The Fluke 700 series maps battery state during that cycle — skipping it causes the instrument to throw premature low-battery warnings on the first measurement session.

BMS lockout after the calibrator sat unused in a carry case for months

Ni-MH cells self-discharge over storage. If the pack voltage drops below roughly 5.4V — the BMS sleep threshold — the charger sees the pack as absent and refuses to begin a charge cycle. The instrument also will not power on. To recover it, apply a trickle charge at 100–200mA directly to the pack terminals for 10–15 minutes to push voltage above 6V, then transfer to the standard dock. Once the BMS re-initialises, a normal charge cycle completes without issue.

Readings resetting or logging gaps during a sustained measurement session

This happens when sustained sensor load — multiple loops active, output sourcing running — pulls enough current to cause a brief voltage sag that the instrument interprets as a power fault. It is not a capacity problem; it is a cell impedance issue in aged or cold packs. A freshly charged pack at room temperature handles the combined draw without dropout. If sags persist after a full charge, the pack has degraded beyond recovery and needs replacement.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Fluke
Fit Model
700 Calibrator740 Calibrator744 CalibratorDSP-100DSP-2000DSP-4000DSP-4000PLDSP4100DSP4300 cable testerImpulse 6000DImpulse 7000DP
Part Number
116-066668225BP7235

Specifications

Battery typeNi-MH
Voltage7.2V
Capacity2500mAh
Wh18Wh
Dimensions153.20 x 54.90 x 20.90mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.