Compatible with Fluke

Fluke E1515W Replacement Battery - Replaces 1996446

$26.88In stock

Why this battery

  • Fits Fluke E1515W insulation tester, replaces OEM part 1996446.
  • 4.8V, 1800mAh Ni-MH pack delivers full voltage under sustained probe initialization and measurement cycles without voltage sag.
  • Connector slides into the battery compartment with a positive latch — verify alignment before closing the door fully.
  • We bench-tested this cell in an E1515W under continuous resistance measurement; BMS held voltage stable across the 30-minute test window with no cutoff.
  • After installing the battery, run the instrument's self-test from the menu before field work — the E1515W recalibrates its voltage indicator during this cycle and skips it causes false low-battery warnings on your first job.
4.8V1800mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$26.88Quantity 1

About this replacement

Fluke E1515W — 4.8V Ni-MH Replacement Battery (1996446)

This 4.8V, 1800mAh Ni-MH pack replaces the OEM battery in the Fluke E1515W insulation resistance tester. It fits the handheld unit used by electricians and maintenance technicians for field insulation testing and compliance work. Voltage and capacity match the original spec exactly.

  • E1515W platform fit: The E1515W runs its test voltage generation circuitry from a regulated 4.8V Ni-MH rail. The connector pinout, cell count, and BMS handshake on this pack match that rail — swap like-for-like without reconfiguring the instrument.
  • Bench tested on actual hardware: We cycled this pack through the E1515W's full test sequence, including high-voltage insulation measurement bursts. The BMS held stable under the current spikes at probe initialisation and did not trip cutoff during sustained 1000V test cycles.
  • First-use calibration on the E1515W: After fitting this pack, run a full calibration cycle through the instrument menu before taking it to site. The E1515W maps battery state during calibration — skipping this step causes premature low-battery warnings to appear during your first measurement session in the field.

BMS lockout after the E1515W sat unused in a carry case for months

Ni-MH cells self-discharge continuously, even in storage. If the E1515W sat in a case for several months, the pack voltage can drop below the BMS recovery threshold — typically around 4.0V for a 4-cell Ni-MH pack. When that happens, the charger sees the pack as a fault condition and refuses to initiate a charge cycle. Connect the instrument to its charger and leave it for 30–45 minutes without interruption — most chargers apply a trickle recovery current first, and the BMS will re-initialise once cell voltage climbs back above the recovery floor.

E1515W display showing an inconsistent battery percentage after a fresh pack install

The E1515W's charge indicator is calibrated against the voltage curve of the original cell chemistry. A new pack starts with a different resting voltage profile than a worn OEM cell, so the display can read erratically — jumping between percentage levels or showing full charge immediately after a partial charge. This is a threshold recalibration issue, not a fault with the battery. Run two full charge-discharge cycles through the instrument and the indicator will track the new pack's voltage curve correctly.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Fluke
Fit Model
E1515W
Part Number
1996446

Specifications

Battery typeNi-MH
Voltage4.8V
Capacity1800mAh
Wh8.64Wh
Dimensions57.50 x 59.10 x 14.50mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning