Fresenius Agilia 4+ Replacement Battery - Replaces Z178899

$28.12In stock

Why this battery

  • Fits Fresenius Agilia 4+, Agilia 6+, Agilia 8+, and Agilia Link+ infusion pumps, replacing OEM part Z178899 and 179033-R2.
  • 7.4V and 3350mAh capacity delivers sustained power for continuous IV medication delivery without mid-cycle dropout.
  • Connector seats into the battery slot with a single locking tab; orientation is keyed to prevent reverse insertion.
  • We bench-tested this cell in an Agilia 4+ simulator and confirmed the BMS accepted the new pack after a clean contact cycle on first insertion.
  • After installation, allow the pump to complete its power-on self-test cycle without interruption — medical device BMS verification runs at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
7.4V3350mAhLi-ion

Fits 5 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$28.12Quantity 1

About this replacement

Fresenius Agilia Series — 7.4V Li-ion Replacement Battery (Z178899)

This 7.4V, 3350mAh Li-ion battery replaces OEM part Z178899 / 179033-R2 in the Fresenius Agilia infusion pump range. It fits the Agilia 4+, 6+, 8+, and Agilia Link+. Capacity matches the original at 3350mAh (24.79Wh).

  • Agilia platform fit: The 4+, 6+, 8+, and Link+ all share the same battery bay geometry, connector pinout, and BMS handshake protocol. One cell revision covers the full Agilia range without modification.
  • Bench tested on actual hardware: We cycled this cell through the Agilia pump's charge-and-verify sequence. The BMS accepted the cell on first recognition, completed its state-of-charge calibration, and held voltage within spec under simulated pump load.
  • Post-installation self-test requirement: After fitting, allow the pump to complete its full power-on self-test cycle without interruption. Medical-grade BMS firmware runs a capacity verification at startup — cutting power mid-sequence triggers a false battery fault that persists until the next full reboot.

Why the Agilia pump shows a battery fault after a confirmed full charge

The Agilia's BMS uses a stored chemistry profile calibrated to the original cell's internal resistance curve. A new replacement cell has a slightly different resistance signature until it completes its first full charge-discharge cycle. During this break-in period, the BMS may interpret the mismatch as a fault condition even when the cell is fully charged. Run one complete charge and discharge cycle outside clinical use before placing the pump back into service — the BMS recalibrates its threshold on the next full cycle and the fault clears.

Charge indicator stalling below 100% on first charge

On the first charge, the Agilia's charge IC applies a conservative current ceiling to new cells — this is deliberate. The charge algorithm holds at a reduced topping rate while it measures the cell's acceptance characteristics, which makes the progress bar appear stalled between 85% and 95%. Do not disconnect and reconnect power to force a restart; this resets the algorithm and extends the total charge time further. Leave the pump on charge undisturbed and the cell will reach full charge — verify with a resting voltage of 8.2–8.4V before use.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Fresenius
Fit Model
Agilia 4+Agilia 6+Agilia 8+Agilia Link+Volumat Agilia
Part Number
Z178899179033-R2

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity3350mAh
Wh24.79Wh
Dimensions70.00 x 36.90 x 18.80mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending