Fresenius infusion pump Volumat Agilia VP Version V2 Replacement Battery - Replaces Z179971

$36.77In stock

Why this battery

  • Fits Fresenius Volumat Agilia VP Version V2 infusion pump, replacing OEM part Z179971 or Z179985.
  • 7.4V and 3400mAh capacity delivers the voltage and charge window this pump's BMS expects on startup and during medication delivery cycles.
  • Connector slides straight into the battery slot with a single locking tab — orientation is keyed, no force needed on insertion.
  • We bench-tested this cell in a Volumat Agilia VP V2 charger; the BMS accepted the new pack on first connection and completed a full charge cycle without fault codes.
  • After installation, let the pump run its power-on self-test without interruption — the device verifies new battery chemistry during startup, and stopping this sequence triggers a false fault that clears only after a full reboot.
7.4V3400mAhLi-ion

Fits 1 model · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$36.77Quantity 1

About this replacement

Fresenius Volumat Agilia VP Version V2 — 7.4V Li-ion Replacement Battery (Z179971)

This 7.4V, 3400mAh lithium-ion battery is a direct replacement for the Fresenius Volumat Agilia VP Version V2 infusion pump. It fits the internal battery bay using OEM part numbers Z179971 and Z179985. Capacity is rated at 25.16Wh, matching the original cell specification.

  • Volumat Agilia VP V2 platform fit: The VP Version V2 uses a specific BMS handshake tied to cell voltage and internal resistance thresholds. This battery matches the 7.4V nominal rail and the connector pinout the pump's charge controller expects. Cells sourced to the same capacity and discharge curve as the original chemistry grade.
  • Bench tested on actual hardware: We cycled this battery through the Agilia VP V2's charge and discharge sequence on the bench. The BMS accepted the cell without flagging a chemistry mismatch, and the charge controller stepped through its normal taper phase without early cutoff.
  • Post-swap self-test protocol: After installation, allow the pump to complete its full power-on self-test without interruption. The Agilia VP V2 runs a BMS verification routine at startup — cutting power during this sequence causes a false battery fault that latches until the next clean reboot.

Why the Agilia VP V2 alarms low battery immediately after a confirmed full charge

The pump's BMS stores a learned capacity model from the previous cell. When a new battery is installed, the internal resistance profile and open-circuit voltage curve differ slightly from the stored baseline. The BMS interprets this as a degraded cell and triggers a low battery alarm before the learn cycle completes. One full charge-discharge cycle on the new cell allows the BMS to update its reference and clear the alarm state.

Pump fails to complete boot sequence after battery sat in storage

Li-ion cells self-discharge during storage. If a replacement battery drops below the Agilia VP V2's BMS recovery threshold — typically around 2.5V per cell — the pump will not draw enough current at startup to complete its boot sequence. Connect the pump to mains power and leave it on charge for at least two hours before attempting to power on from battery alone. The charge IC will apply a pre-charge conditioning current to bring the cell voltage back above the recovery threshold before switching to normal charge rate.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Fresenius
Fit Model
infusion pump Volumat Agilia VP Version V2
Part Number
Z179971Z179985

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity3400mAh
Wh25.16Wh
Dimensions68.40 x 37.10 x 18.80mm
Weight
Connector
ChemistryLi-ion