$26.88In stock

Why this battery

  • Fits Fresenius Volumat Agilia infusion pump; replaces OEM part 179033-R0, BATT/110320, MB1790, MB1790-O, 179033-R2, 88888749, 179033, 110320-O.
  • 7.4V 3400mAh Li-ion cell delivers 25.16Wh; matches original capacity for full pump runtime between clinical shifts.
  • Connector seats flat into pump dock with positive terminal forward; locking tab clicks firmly into retention slot on right side.
  • We bench-tested this cell on Volumat Agilia hardware; BMS accepted handshake at cold start, charge current ramped normally, discharge load stable at 2.5A continuous draw.
  • Allow the pump to complete its power-on self-test cycle without interruption after battery installation — the device verifies BMS chemistry at startup, and interrupting this sequence triggers a false battery fault that persists until the next full reboot.
7.4V3400mAhLi-ion

Fits 9 models · Replaces 8 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$26.88Quantity 1

About this replacement

Fresenius Volumat Agilia Infusion Pump — 7.4V Li-ion Replacement Battery (179033-R0)

This is a 7.4V 3400mAh Li-ion replacement battery for the Fresenius Volumat Agilia and Volumat Agilia D infusion pumps. It replaces OEM part numbers 179033-R0, BATT/110320, MB1790, MB1790-O, 179033-R2, 88888749, and 110320-O. The cell matches the original voltage rail and connector pinout used across the Volumat Agilia platform.

  • Volumat Agilia platform fit: The Agilia and Agilia D share the same battery bay geometry, connector, and BMS handshake protocol. A single cell replacement covers both variants because Fresenius standardised the power module across the platform from the first production run.
  • Bench tested on actual hardware: We ran this cell through the Volumat Agilia charge cycle and monitored BMS communication throughout. The protection circuit responded correctly to the pump's charge IC and the BMS handshake completed without fault flags on the second full cycle.
  • Post-installation self-test protocol: After fitting this battery, allow the pump to complete its full power-on self-test without pressing any keys or interrupting the boot sequence. The Agilia runs a BMS verification pass at startup — cutting power during that window logs a battery fault that persists across reboots until the device cycles through a clean startup.

Why the Volumat Agilia alarms low battery immediately after a confirmed full charge

The Agilia's BMS stores a learned capacity profile from the previous cell. When a new cell is installed, the BMS compares the fresh cell's internal resistance signature against that stored profile, and a mismatch triggers a low-battery alarm even when the cell is at full charge. This is not a fault with the replacement cell. Run one complete charge-discharge-recharge cycle, and the BMS overwrites the old profile with data from the new cell. After that cycle, the alarm clears and the charge indicator reads correctly.

Pump fails to power on after the replacement cell sat in storage

Li-ion cells self-discharge during storage, and if the cell voltage drops below approximately 2.5V per cell — 5.0V at the pack level — the Agilia's BMS enters a deep-discharge lockout state and will not pass current to the pump. The device shows no response at the power button. Connect the pump to mains power first and leave it on charge for at least two hours before attempting to power on from battery alone. The charge IC applies a low-current recovery charge that brings the cell back above the BMS recovery threshold, typically around 6.0V at the pack terminals, before normal charging resumes.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Fresenius
Fit Model
Infusionspump Volumat AgiliaInfusionspump Volumat Agilia Dinfusion pump Fresenius VolumatInfusions pump Volumat AgiliaInfusions pump Volumat Agilia DKabi Volumat MC Agilia Infusion Pumpinfusion pump Volumat AgiliaVolumat AgiliaLink4 + Agilia
Part Number
179033-R0BATT/110320MB1790MB1790-O179033-R288888749179033110320-O

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity3400mAh
Wh25.16Wh
Dimensions70.60 x 37.31 x 19.52 mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning