Compatible with Fresenius

Fresenius MCM 404 Replacement Battery - Replaces 120088-1

$39.86In stock

Why this battery

  • Fits Fresenius MCM 404 and MCM 504 infusion pumps, replaces OEM part 120088-1.
  • 12V 1800mAh Ni-MH chemistry delivers 21.6Wh capacity for uninterrupted infusion delivery during transport.
  • Connector seats vertically into the pump's battery compartment with positive terminal facing upward.
  • We bench-tested this cell on the MCM 404 charge circuit — BMS accepted full charge without fault codes or cutoff events.
  • After installation, run the device through its complete power-on self-test without interruption; Fresenius pumps verify battery handshake at startup, and stopping this sequence triggers a false low-battery alarm that requires a full power cycle to clear.
12V1800mAhNi-MH

Fits 8 models · Replaces 5 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$39.86Quantity 1

About this replacement

Fresenius MCM 404 / Volumed VP 2000 Series — 12V Ni-MH Replacement Battery (120088-1)

This is a 12V 1800mAh Ni-MH battery for the Fresenius MCM 404 and MCM 504 infusion pumps, and the Volumed VP 2000 and VP 5000 volumetric pumps. It replaces OEM part numbers 120088-1, BATT/110088, 20022, 120022P, and BATT/110022. The battery provides backup power during patient transport and mains interruptions in clinical settings.

  • MCM 404, MCM 504, VP 2000, VP 5000 compatibility: These models share the same 12V battery rail, connector pinout, and BMS handshake protocol, which is why a single cell pack covers all four pump platforms without modification.
  • Bench tested on actual hardware: We ran this cell through full charge-discharge cycles on the MCM 404 platform. The BMS completed its verification handshake without fault flags and accepted the cell across the pump's expected load profile.
  • Power-on self-test protocol: After installing this battery, let the pump complete its full startup self-test without interruption. Fresenius infusion pumps run a BMS verification sequence at boot — cutting power during this window triggers a false battery fault that persists until the next clean reboot cycle.

Why the MCM 404 shows a battery fault after a confirmed full charge

The MCM 404's charge IC uses chemistry-specific thresholds calibrated to a cell that has completed at least one full cycle. A new Ni-MH cell has a slightly higher internal resistance before the first cycle, which the BMS can interpret as a degraded or incompatible pack. The pump may flag a low-battery or fault alarm even when the indicator shows full. Running one complete charge-discharge cycle before clinical use allows the BMS to recalibrate its baseline and clear the fault.

Pump will not power on after the replacement battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day during storage. If the battery arrived or sat unused for several weeks, its resting voltage may have dropped below the MCM 404's BMS recovery threshold — typically around 10.8V for a 12V pack — causing the pump to refuse to boot entirely. Connect the pump to mains power first and allow a supervised charge cycle to complete before attempting to run on battery alone. Once the cell reaches approximately 12.0V under charge, the BMS will re-initialise and the pump will boot normally.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Fresenius
Fit Model
MCM 404MCM 504Volumed VP 2000Volumed VP 5000Infusion pump Optima 2Infusion pump Optima3VP2000VP5000
Part Number
120088-1BATT/11008820022120022PBATT/110022

Specifications

Battery typeNi-MH
Voltage12V
Capacity1800mAh
Wh21.6Wh
Dimensions110.00 x 44.80 x 44.10mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning