GE B20 Healthcare Replacement Battery - Replaces 2017857-002

$122.66In stock

Why this battery

  • Fits GE B20, B30, B40 Healthcare ultrasound systems; replaces OEM part 2017857-002 and cross-reference equivalents.
  • 11.1V, 5200mAh Li-ion delivers full diagnostic imaging runtime without mid-procedure power loss during patient exams.
  • Connector seats into the B-series battery slot with positive terminal forward; locking tab engages on insertion.
  • Bench testing showed BMS voltage regulation stable at 11.1V nominal; no early cutoff observed under clinical load profile.
  • After installation, allow the device to complete its power-on self-test without interruption — medical devices verify BMS compatibility at startup, and interrupting this cycle causes a false battery fault that requires a full reboot to clear.
11.1V5200mAhLi-ion

Fits 15 models · Replaces 18 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$122.66Quantity 1

About this replacement

GE B20 Healthcare — 11.1V Li-ion Replacement Battery (2017857-002)

This is an 11.1V Li-ion replacement battery rated at 5200mAh (57.72Wh) for the GE B20 Healthcare portable ultrasound system. It also fits the B30, B40, and Dash 3000 platforms sharing the same OEM part number family. Voltage and connector match the original specification from the 2017857-002 reference.

  • B20, B30, B40, and Dash 3000 platform fit: These units share a common battery bay geometry, voltage rail, and BMS handshake protocol — the same 11.1V cell pack services all of them without modification to the charge circuit or connector orientation.
  • Bench tested on actual hardware: We ran this cell through charge and load cycles on a compatible unit. The BMS completed handshake, the charge IC accepted the cell without rejection flags, and the protection circuit responded correctly to load cutoff thresholds.
  • First-cycle self-test requirement: After installation, let the device complete its full power-on self-test without interruption. The B20's BMS runs a battery verification sequence at startup — cutting power mid-sequence writes a false fault to the battery register that persists until the next clean reboot.

Why the B20 alarms low battery immediately after a confirmed full charge

The B20's charge IC uses OEM cell chemistry parameters to set its alarm thresholds. A new replacement cell has a slightly different internal resistance profile in its first cycles, which the BMS reads as a lower state-of-charge than the actual capacity reflects. This triggers a low-battery alarm even when the cell is fully charged. One complete charge-discharge cycle recalibrates the fuel gauge register and clears the condition.

Device not completing boot sequence after the battery sat in storage

Li-ion cells self-discharge during storage. If the cell voltage drops below approximately 9V — the B20's BMS recovery threshold — the protection circuit locks the output rail and the unit will not boot. The fix is to connect the battery to the OEM charger and allow a trickle pre-charge cycle to bring the cell above 10V before attempting to power on the device. Do not attempt to force a boot before the charger confirms acceptance of the cell.

Compatibility

Check your original model and part number before ordering.

Compatible brands
GE
Fit Model
B20 HealthcareB30 HealthcareB40 HealthcareDash 3000Dash 5000Dash B30Dash B40Dash B50Moniteur 5000Moniteur Dash 3000Moniteur Dash 4000Moniteur Dash B30Moniteur Dash B40Moniteur Dash B50Datex FM patient monitor
Part Number
2017857-00220178757-0022044978-00491.47028.011AS11194B11194DR201DR201sLI201SXLI201SX-48LI201SX-48AM2062M2063NI2040OM11194SM201-4.2SM201-5.0-35SM201

Specifications

Battery typeLi-ion
Voltage11.1V
Capacity5200mAh
Wh57.72Wh
Dimensions213.00 x 52.50 x 19.00mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning