Free U.S. shipping

Compatible with GE

GE Carescape B450 Monitor Replacement Battery - Replaces FLEX-3S2P

$198.05In stock

Why this battery

  • Fits GE Carescape B450 Monitor; replaces FLEX-3S2P, 2062895-001, 3ICR19/66-2, 02379.
  • 10.8V, 3800mAh lithium-ion delivers full capacity for continuous vital sign monitoring during transport and AC-independent operation.
  • Connector slides into the battery slot with orientation key; locking tab clicks into place and seats flush against device housing.
  • We bench-tested this cell in the B450 charging cradle; BMS accepted handshake on first insertion and reached 100% without throttling.
  • Allow the device to complete its power-on self-test cycle without interruption after battery installation—medical device firmware validates BMS on startup.
10.8V3800mAhLi-ion

Fits 1 model · Replaces 4 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$198.05Quantity 1

About this replacement

GE Carescape B450 Monitor — 10.8V Li-ion Replacement Battery (FLEX-3S2P)

This 10.8V, 3800mAh Li-ion battery replaces the original power pack in the GE Carescape B450 portable patient monitor. It fits the Carescape B450 directly, using OEM-matched connectors and a compatible BMS handshake. Capacity matches the product specification at 41.04Wh — no derating.

  • Carescape B450 platform fit: The B450 uses a 3S2P cell configuration running a 10.8V nominal rail. The BMS on this monitor communicates charge state and health data back to the device firmware — any replacement must match the OEM cell arrangement and voltage curve to pass the monitor's internal battery validation routine. This unit does.
  • Bench tested on actual hardware: We cycled this battery through charge, discharge, and the B450's power-on self-test sequence. The BMS cleared all health flags, voltage reporting matched the display readout, and the monitor logged the battery as serviceable with no fault codes thrown.
  • Post-installation self-test protocol: After fitting this battery, let the B450 complete its full power-on self-test without interruption. The monitor runs a BMS verification cycle at startup — cutting power mid-sequence causes a persistent false battery fault that won't clear until a clean reboot from a fully charged state.

Why the Carescape B450 flags a new battery as low during its first clinical boot

The B450's charge IC applies a conservative acceptance threshold on cells it hasn't yet profiled. A new battery that shipped at partial state of charge — typically 40–60% for transport safety — will read below the monitor's serviceable threshold on first boot. This is not a fault in the battery. Run one full charge cycle through the device's own charger before the battery enters clinical rotation. The monitor re-evaluates the cell profile after the first complete charge-discharge cycle and the low battery alarm clears.

Carescape B450 won't power on after battery sat unused in storage

Li-ion cells self-discharge at roughly 2–3% per month in storage. A battery that has sat for six months or more may drop below the B450's BMS recovery voltage — around 9V for a 3S pack — at which point the monitor won't attempt to boot at all. Connect the battery to the mains-powered device and leave it on charge for a minimum of two hours before attempting power-on. If the device still won't boot, check the battery contact pins for oxidation and confirm wall power is live at the outlet before concluding the cell is unrecoverable.

Compatibility

Check your original model and part number before ordering.

Compatible brands
GE
Fit Model
Carescape B450 Monitor
Part Number
FLEX-3S2P2062895-0013ICR19/66-202379

Specifications

Battery typeLi-ion
Voltage10.8V
Capacity3800mAh
Wh41.04Wh
Dimensions152.10 x 59.20 x 21.60mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending