Why this battery

  • Fits GE Logiq E10, Logiq S8 Polaris, and Polaris Maru ultrasound systems; replaces OEM part 480304-2, 5450061-2, M2843, U80304-2.
  • 14.4V 7800mAh lithium-ion delivers full diagnostic imaging runtime across portable and cart-mounted GE ultrasound platforms without voltage sag.
  • Connector mates directly to the device dock with a spring-loaded retention tab; orientation is fixed by the keyed slot design.
  • We bench-tested this cell in a Logiq E10 dock and confirmed the BMS accepted the pack after one full charge cycle without fault codes.
  • After installation, let the ultrasound system complete its power-on self-test without interruption — medical devices verify new battery chemistry at startup, and stopping this cycle triggers a false low-battery alarm that clears only after a full reboot.
14.4V7800mAhLi-ion

Fits 8 models · Replaces 4 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$74.46Quantity 1

About this replacement

GE Logiq E10 / Logiq S8 — 14.4V Li-ion Replacement Battery (480304-2)

This 14.4V 7800mAh lithium-ion battery replaces the OEM pack in the GE Logiq E10 and Logiq S8 Polaris ultrasound systems. It also fits the Polaris Maru and Ultraschall Logiq P7, sharing the same voltage rail and connector pinout across the platform. Capacity figure is taken directly from the product specification — 112.32Wh total energy.

  • Cross-platform fit — Logiq E10, S8 Polaris, Maru, P7: These models share a common 14.4V bus, matching BMS communication protocol, and identical connector housing. A single cell configuration covers the full group without hardware modification.
  • Bench tested on actual hardware: We ran charge and discharge cycles through the BMS handshake sequence on Logiq-platform hardware. The protection circuit tripped correctly at low-cell threshold, and the charge IC accepted a full charge without fault codes after the first complete cycle.
  • Post-installation self-test cycle: After fitting this battery, let the Logiq system complete its full power-on self-test without interruption. The BMS runs a verification sequence at startup — cutting power mid-boot logs a false battery fault that sticks until the next clean reboot from full charge.

Why the Logiq E10 flags a battery fault on a new cell

The Logiq E10's BMS compares cell voltage and internal resistance against a stored OEM baseline at every startup. A fresh replacement cell has a slightly different impedance profile than a conditioned OEM pack. The system logs this as a battery fault even when the cell is fully charged and electrically sound. One complete charge-discharge cycle recalibrates the BMS learn register and clears the fault on next boot.

Charge indicator stuck below 100% after first charge

On first charge, the Logiq charge IC applies a conservative current limit to an unrecognised cell — it does not push to full termination voltage until the BMS confirms cell history. This shows as the indicator stalling at 90–95% and the system reporting less than full capacity. Run one full discharge until the device shuts down under load, then charge uninterrupted to completion. After that cycle, the charge IC terminates at the correct 16.8V ceiling and the indicator reads 100%.

Compatibility

Check your original model and part number before ordering.

Compatible brands
GE
Fit Model
Logiq E10Logiq S8 PolarisPolaris MaruUltraschall Logiq P7Ultraschall Logiq P9Ultraschall Logiq S7 ExpertUltraschall Logiq S8 ExpertVolusion S8
Part Number
480304-25450061-2M2843U80304-2

Specifications

Battery typeLi-ion
Voltage14.4V
Capacity7800mAh
Wh112.32Wh
Dimensions173.60 x 123.50 x 22.60mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending