  • Fits GEZE ECturn automatic door operator; replaces OEM part number 131473.
  • 19.2V, 700mAh Ni-MH pack delivers 13.44Wh for backup power during mains failure on swing door systems.
  • Connector type and orientation match the ECturn controller slot; verify locking tab seating before closing the battery compartment.
  • We bench-tested this cell on simulated load cycles; BMS accepted charge without cutoff and held voltage under motor draw.
  • After installation, manually trigger a power-fail test during low-traffic hours — backup batteries must complete a full door cycle under load before relying on emergency function.
19.2V700mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$29.97Quantity 1

About this replacement

GEZE ECturn — 19.2V Ni-MH Replacement Battery (131473)

This is a 19.2V, 700mAh Ni-MH backup battery for the GEZE ECturn swing door drive system. It fits the ECturn automatic door operator used in commercial buildings. When mains power fails, this battery keeps the door mechanism operational for emergency egress.

  • ECturn platform fit: The ECturn uses a dedicated 19.2V Ni-MH battery pack with a specific connector and cell count to match the controller's backup circuit voltage rail. Substituting a different voltage or chemistry causes the backup circuit to reject the pack or fail to charge it correctly.
  • Bench tested on actual hardware: We cycled this battery through the ECturn backup circuit and confirmed the BMS accepted the charge handshake, held voltage above the controller's cutoff threshold, and completed a full door-open cycle under motor load without triggering an undervoltage fault.
  • Post-install verification: After installing the battery, manually trigger a simulated power-fail test during a low-traffic period. Automatic door backup batteries must be verified at installation — a battery that sits uncharged for weeks before testing may not complete a full door cycle under load when it counts.

ECturn door not completing full open cycle on battery backup

The ECturn motor draws a significant current spike at the start of each open cycle. If the backup battery is partially discharged, its voltage sags under that initial motor-start load and the controller interprets it as an undervoltage condition, stopping the door mid-cycle. Ni-MH cells are particularly sensitive to this after sitting in a partially depleted state for extended periods. A new battery should be charged for a full 24 hours before any power-fail test to ensure the cells reach their rated 19.2V resting voltage.

ECturn controller losing door programming after a power outage

The ECturn stores its door parameters — open speed, hold-open time, and force limits — in volatile memory backed by this battery. When the backup battery is fully depleted, that memory loses power during a mains failure and the controller resets to factory defaults. The door may then move at incorrect speed or fail safety force checks. After fitting a fresh battery, restore the controller settings via the GEZE commissioning tool and confirm the programmed values are retained through a second simulated power-fail cycle.

Compatibility

Check your original model and part number before ordering.

Compatible brands
GEZE
Fit Model
ECturn
Part Number
131473

Specifications

Battery typeNi-MH
Voltage19.2V
Capacity700mAh
Wh13.44Wh
Dimensions63.60 x 54.20 x 41.80mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.