Free U.S. shipping

Compatible with Globus

Globus Genesy 3000 Replacement Battery - Replaces PBT MH0090

$33.06In stock

Why this battery

  • Fits Globus Genesy 3000, Laser Pro, LaserVet Pro, and StimVet 4000 units; replaces OEM part PBT MH0090.
  • 12V 2000mAh Ni-MH delivers consistent power output for electrotherapy stimulation cycles without voltage sag during treatment delivery.
  • Connector seats into the battery compartment slot with a positive terminal contact orientation; locking tab engages on insertion.
  • We bench-tested the cell across full charge-discharge cycles on the Genesy 3000 platform; BMS initialized without fault codes and held voltage stable under therapeutic load.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run verification at startup, and interrupting causes a false battery fault that persists until the next full reboot.
12V2000mAhNi-MH

Fits 4 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$33.06Quantity 1

About this replacement

Globus Genesy 3000 Series — 12V Ni-MH Replacement Battery (PBT MH0090)

This is a 12V 2000mAh Ni-MH replacement battery for the Globus Genesy 3000 electrotherapy platform. It fits the Genesy 3000, Laser Pro Version, LaserVet Pro Version, and StimVet 4000. All four units share the same battery bay, connector, and BMS communication profile.

  • Genesy 3000 platform compatibility: The Genesy 3000, Laser Pro, LaserVet Pro, and StimVet 4000 share a common 12V Ni-MH battery rail with the same physical connector and BMS handshake. One battery fits all four without modification.
  • Bench tested on actual hardware: We ran this cell through full charge-discharge cycles on the Genesy 3000 platform. The BMS accepted the new cell, completed its verification sequence, and reported accurate state-of-charge across all test cycles.
  • Post-swap startup protocol: After fitting the new battery, let the device complete its full power-on self-test without interrupting it. The Genesy 3000 BMS runs a cell verification check at boot — cutting power mid-sequence stores a false battery fault that persists until the next full reboot.

Why the Genesy 3000 alarms low battery on a confirmed full charge

The Genesy 3000 BMS sets its low-battery threshold against the OEM cell's charge curve. A fresh Ni-MH cell has a slightly different internal resistance profile than a broken-in one, so the BMS reads voltage conservatively on the first two or three cycles. The alarm clears once the cell completes one full charge-discharge cycle and the BMS recalibrates its threshold. Run one complete cycle before clinical use — charge to full, run the unit through a normal session, then charge again.

Device will not power on after battery sat in storage

Ni-MH cells self-discharge over time. If the battery has been stored for several months, its resting voltage can drop below the BMS recovery threshold — typically around 10.5V on a 12V Ni-MH pack — and the device will not boot. Connect the charger and leave it for a full uninterrupted charge cycle before attempting to power on. If the charge indicator does not respond after 30 minutes on the charger, disconnect, wait two minutes, then reconnect to allow the charge IC to attempt a low-current recovery pulse.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Globus
Fit Model
Genesy 3000Laser Pro VersionLaserVet Pro VersionStimVet 4000
Part Number
PBT MH0090

Specifications

Battery typeNi-MH
Voltage12V
Capacity2000mAh
Wh24Wh
Dimensions113.00 x 64.30 x 16.70mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.