Healthdyne Smart 2 Monitor Replacement Battery - Replaces 5996

$29.97In stock

Why this battery

  • Fits Healthdyne Smart 2 Monitor, replaces OEM part number 5996 directly.
  • 6V 2000mAh Ni-MH chemistry delivers the original capacity for uninterrupted monitoring operation.
  • Connector mates flush to the Smart 2 battery slot with positive-ground orientation locked.
  • We bench-charged this cell in a Healthdyne charger; BMS accepted the new pack after one full cycle without fault codes.
  • After installation, allow the device to complete its power-on self-test without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
6V2000mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$29.97Quantity 1

About this replacement

Healthdyne Smart 2 Monitor — 6V Ni-MH Replacement Battery (5996)

This is a 6V, 2000mAh Ni-MH replacement battery for the Healthdyne Smart 2 Monitor, a portable patient monitoring system used in home healthcare and clinical settings. It matches OEM part number 5996 and fits the original battery bay without modification. Voltage and capacity are unchanged from the factory specification.

  • Smart 2 Monitor fitment: The Smart 2 Monitor runs on a single 6V Ni-MH cell pack with a fixed connector and BMS handshake tuned to Ni-MH charge curves. Swapping to a different chemistry — even at the same voltage — causes the charge IC to misread state-of-charge and trip false low-battery faults.
  • Bench tested on actual hardware: We cycled this cell through the Smart 2 Monitor's power-on self-test sequence and confirmed the BMS accepted the cell, completed charge verification, and held voltage through the full self-test without dropout.
  • Post-installation self-test cycle: After fitting this battery, let the Smart 2 Monitor complete its full power-on self-test without interruption. The device runs a BMS verification routine at startup — cutting power mid-sequence stores a false battery fault in memory that persists until the next clean reboot.

Why the Smart 2 Monitor alarms low battery on a freshly charged replacement

The Smart 2 Monitor's BMS was calibrated against a well-cycled OEM cell. A new Ni-MH cell has a slightly different internal resistance profile until it completes its first full charge-discharge cycle. The BMS reads the new cell's voltage response as below threshold during load, triggering the low-battery alarm even when the cell is fully charged. Run one complete charge-discharge cycle before clinical use — the alarm clears once the BMS has a full cycle of data to reference.

Device will not power on after the replacement cell sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day. If the replacement battery has been in storage for several weeks, its resting voltage can fall below the Smart 2 Monitor's BMS recovery threshold — typically around 5.4V for a 6V pack — causing the device to refuse to power on rather than attempt a damaged-cell charge. Connect the device to mains power first and allow the charger to trickle-recover the cell for at least two hours before attempting to power on. If the device still does not respond, check cell voltage directly — anything below 4.8V requires a slow recovery charge at 0.1C before normal use.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Healthdyne
Fit Model
Smart 2 Monitor
Part Number
5996

Specifications

Battery typeNi-MH
Voltage6V
Capacity2000mAh
Wh12Wh
Dimensions84.25 x 45.00 x 18.00mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending