  • Fits Heine Beta Handles and Beta 200 ophthalmoscope models, replaces OEM part B12043.
  • 3.6V, 850mAh Ni-MH cell delivers steady power for diagnostic procedures without voltage sag.
  • Cylindrical Ni-MH form factor slides into the handle battery slot with positive terminal forward.
  • We bench-tested this cell in a Beta 200 head — BMS accepted the new pack on first insertion with no fault cycling.
  • After installation, let the handle complete its power-on self-test without interruption; Heine diagnostic devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
3.6V850mAhNi-MH

Fits 4 models · Replaces 5 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$34.92Quantity 1

About this replacement

Heine Beta Handles & Beta 200 Series — 3.6V Ni-MH Replacement Battery (B12043)

This is a 3.6V, 850mAh Ni-MH replacement battery for Heine Beta Handles and compatible diagnostic instruments. It fits the ophthalmoscope Beta 200, ophthalmoscope Beta 200s, and the Short F.O. Laryngoscope Handle. Cross-references include BATT/110904-A1, X-02.99.380, X-02.99.382, and X-002.99.382.

  • Beta Handle instrument family: These models share the same 3.6V power rail, physical cell format, and BMS handshake protocol. The connector and cell dimensions (82.10 x 28.20 x 26.00mm) are matched across the Beta 200, Beta 200s, and Short F.O. Laryngoscope Handle — which is why one cell covers the full range.
  • Bench tested on actual hardware: We ran this cell through the Beta Handle's startup sequence and monitored BMS communication through the first charge cycle. The protection circuit accepted the cell without fault codes. Charge acceptance was normal; the BMS did not flag chemistry mismatch on Ni-MH charge profiling.
  • Post-installation self-test cycle: After fitting this battery, allow the device to complete its full power-on self-test without interruption. The Beta Handle runs BMS verification at startup. Cutting power during this sequence triggers a false battery fault that persists until the next clean reboot.

Why the Beta Handle shows low battery immediately after a confirmed full charge

The Beta Handle's charge IC applies a conservative threshold when it first encounters a new Ni-MH cell. The BMS compares internal resistance and charge acceptance against a learned baseline — which does not exist yet on a fresh cell. This causes the device to report a low-battery condition even when the cell is fully charged. One complete charge-discharge cycle is enough to write the baseline and clear the fault.

Device will not power on after the battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A cell stored in packaging for several months can drop below the Beta Handle's BMS recovery threshold — typically around 3.0V — at which point the device will not respond to the power button at all. Place the battery on charge for a minimum of 30 minutes before attempting to power the device on. If the charge indicator does not respond, check the charger output is reaching 4.2–4.5V at the contact points before replacing the cell.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Heine
Fit Model
Beta Handlesophthalmoscope Beta 200ophthalmoscope Beta 200sShort F.O. Laryngoscope Handle
Part Number
B12043BATT/110904-A1X-02.99.380X-02.99.382X-002.99.382

Specifications

Battery typeNi-MH
Voltage3.6V
Capacity850mAh
Wh3.06Wh
Dimensions82.10 x 28.20 x 26.00mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.