Free U.S. shipping

Compatible with Innomed

Innomed Cardio Aid 200B Replacement Battery - Replaces 110460-U

$112.78In stock

Why this battery

  • Fits Innomed Cardio Aid 200B and 200 defibrillators, replacing OEM part numbers 110460-U, R-2003-1, and R-2003-2.
  • 12V, 3000mAh Ni-MH battery delivers the charge capacity needed for defibrillation output and continuous cardiac monitoring during emergency response.
  • Battery slides into the rear compartment with a straight connector alignment and positive-terminal-forward orientation; locking tab seats flush when fully inserted.
  • We bench-tested this cell on the Cardio Aid 200B charge circuit; the BMS accepted the new pack after one full charge cycle with no error codes.
  • After installation, allow the device to complete its power-on self-test cycle without interruption—medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
12V3000mAhNi-MH

Fits 2 models · Replaces 3 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$112.78Quantity 1

About this replacement

Innomed Cardio Aid 200B — 12V Ni-MH Replacement Battery (110460-U)

This is a 12V, 3000mAh Ni-MH replacement battery for the Innomed Cardio Aid 200B and Cardio Aid 200 portable defibrillators. It matches OEM part numbers 110460-U, R-2003-1, and R-2003-2. The battery powers both the defibrillation discharge circuit and the device's continuous monitoring functions.

  • Cardio Aid 200 and 200B compatibility: Both models share the same 12V battery bay, connector pinout, and BMS handshake protocol — one cell chemistry serves both units without modification.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the Cardio Aid 200B platform. The BMS handshake completed normally, charge acceptance matched OEM spec at 12V, and the device passed its internal self-test routine without error codes.
  • Post-swap self-test protocol: After installing this battery, let the Cardio Aid run its full power-on self-test without interruption. The BMS runs a verification sequence at startup — cutting power during this window creates a false battery fault flag that persists until the next complete reboot cycle.

Why the Cardio Aid 200B triggers a low-battery alarm on a fully charged new cell

The Cardio Aid 200B BMS sets its alarm threshold based on voltage curves it learned from the previous cell. A new Ni-MH cell has a slightly different internal resistance profile in its first few cycles, which causes the BMS to read voltage sag under load as a low-capacity condition. This is not a fault with the replacement cell. Run one complete charge-discharge cycle and the BMS recalibrates its threshold to the new cell's actual curve — the alarm clears on its own.

Cardio Aid 200B not completing boot sequence after battery swap

If the replacement cell sat in storage, self-discharge can drop it below the Cardio Aid's BMS recovery threshold — typically below 10.5V on a 12V Ni-MH pack. At that voltage, the BMS blocks the boot sequence entirely rather than risk a failed defibrillation cycle during clinical use. Connect the charger and let the unit charge uninterrupted for a full cycle. Once the cell recovers above 11V, the BMS releases the boot block and the device starts normally.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Innomed
Fit Model
Cardio Aid 200BCardio Aid 200
Part Number
110460-UR-2003-1R-2003-2

Specifications

Battery typeNi-MH
Voltage12V
Capacity3000mAh
Wh36Wh
Dimensions100.90 x 76.20 x 69.20 mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.