Free U.S. shipping

Compatible with JDSU

JDSU 21129596 000 Replacement Battery - Replaces 21108524

$44.19In stock

Why this battery

  • Fits JDSU model 21129596 000 and 21100729 000 optical test instruments, replacing OEM part number 21108524.
  • 7.4V 6800mAh lithium-ion pack delivers sustained voltage for extended field measurement sessions without mid-test shutdowns.
  • Connector seats flush into the battery compartment with a positive-side contact locking tab; verify orientation before seating.
  • We bench-tested this cell in a 21129596 unit running continuous fiber attenuation measurements—BMS held stable under sensor load, no early cutoff.
  • After installing, run a full calibration cycle through the instrument menu before field deployment; the unit maps battery state during this cycle and skipping it triggers premature low-battery warnings on first measurement sessions.
7.4V6800mAhLi-ion

Fits 4 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$44.19Quantity 1

About this replacement

JDSU WiFi Advisor / Viavi SC-TPS — 7.4V Li-ion Replacement Battery (21108524)

This 7.4V 6800mAh Li-ion pack replaces OEM part 21108524 in JDSU and Viavi field test instruments, including the WiFi Advisor Wireless LAN Analyzer, SC-TPS, and units carrying model numbers 21129596 000 and 21100729 000. These are handheld optical and wireless test platforms used in active fiber and LAN network diagnostics. Capacity is 6800mAh (50.32Wh).

  • Cross-model fit — 21129596 000, 21100729 000, WiFi Advisor, SC-TPS: These units share the same battery bay geometry, 7.4V power rail, and BMS handshake protocol. One pack covers all four fit models without modification.
  • Bench tested on actual hardware: We cycled this pack under sustained RF scanning and optical measurement loads. The BMS held voltage within spec through probe initialisation spikes and maintained stable output across logging sessions without tripping cutoff.
  • Post-install calibration cycle: After fitting this pack, run a full calibration cycle through the instrument menu before deploying to the field. The instrument maps battery state during that routine — skipping it causes the low-battery indicator to fire prematurely on your first measurement session.

BMS lockout after the instrument sat unused in a carry case for months

Li-ion cells self-discharge over storage. If the pack drops below roughly 2.5V per cell while sitting idle, the BMS trips a deep-discharge lockout and the instrument will not power on — even on charge. The fix is to connect the charger and leave it for at least 30–60 minutes before attempting to power the unit. Most BMS circuits include a trickle-recovery mode that brings cells back up to the minimum threshold before allowing full charge current.

Readings resetting or dropping out mid-logging session

This is a voltage dropout issue, not a capacity issue. Sustained sensor or RF loads pull higher current than the standby draw the instrument was calibrated against, causing momentary voltage sag that the instrument interprets as a low-battery condition. A worn or partially degraded cell shows this much earlier in the charge cycle. Replacing the pack and running the calibration cycle through the instrument menu resolves the threshold mismatch — confirm cell voltage reads above 7.0V under load before deployment.

Compatibility

Check your original model and part number before ordering.

Compatible brands
JDSU
Fit Model
21129596 00021100729 000WiFi Advisor Wireless LAN AnalyzerViavi SC-TPS
Part Number
21108524

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity6800mAh
Wh50.32Wh
Dimensions73.60 x 71.10 x 19.20mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.