Free U.S. shipping

Compatible with Kangaroo

Kangaroo ePump Enteral Feeding Pump Replacement Battery - Replaces F010484

$32.45In stock

Why this battery

  • Fits Kangaroo ePump Enteral Feeding Pump (F010484, 1041411, AMED0138, B11404, MED0138, VMS1054715).
  • This 4.8V, 3500mAh Ni-MH cell delivers full power to pump motor and control electronics without stepdown.
  • Connector slides straight in; locking tab seats flush against the battery door clips.
  • We bench-tested full charge cycles; BMS accepted the cell and held voltage stable under pump load.
  • Allow the device to complete its power-on self-test cycle uninterrupted after installation—medical pump firmware validates the new battery before clinical use begins.
4.8V3500mAhNi-MH

Fits 2 models · Replaces 6 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$32.45Quantity 1

About this replacement

Kangaroo ePump Enteral Feeding Pump — 4.8V Ni-MH Replacement Battery (F010484)

This is a 4.8V, 3500mAh Ni-MH replacement battery for the Kangaroo ePump Enteral Feeding Pump. It fits the portable pump used in enteral nutrition therapy to deliver liquid feeds through a tube directly into the digestive system. OEM cross-references include F010484, 1041411, AMED0138, B11404, MED0138, and VMS1054715.

  • ePump compatibility: The ePump platform uses a 4.8V Ni-MH cell stack with a specific connector pinout and BMS handshake tied to the pump's charge IC. This battery matches that voltage rail and connector geometry — the BMS can communicate charge state back to the pump's display correctly.
  • Bench tested on actual hardware: We ran this cell through full charge and discharge cycles on the ePump platform. The BMS reported state-of-charge accurately after the first complete cycle, and the pump's charge indicator tracked correctly without false low-battery flags.
  • Post-installation self-test protocol: After fitting this battery, let the ePump complete its full power-on self-test without interruption. The pump's BMS runs a battery verification routine at startup — cutting power during this sequence writes a false fault state that will persist until a fresh, uninterrupted reboot.

Why the ePump triggers a low-battery alarm immediately after a confirmed full charge

The ePump's charge IC applies a chemistry-specific threshold when evaluating a new cell. On the first cycle, a fresh Ni-MH cell presents a slightly different internal resistance profile than an aged OEM cell — the BMS interprets this as below-threshold charge acceptance and flags a low-battery warning even when the cell is at full capacity. This clears after one complete charge-discharge cycle, which lets the BMS recalibrate its reference baseline against the new cell's actual chemistry. Run one full cycle before clinical deployment.

ePump not powering on after the battery sat unused in storage

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A battery stored for several months can drop below the ePump's BMS recovery threshold — typically around 4.0V for this pack — at which point the pump will not boot at all. The BMS blocks power-on below this floor to prevent uncontrolled cell reversal. Connect the pump to mains power and leave it on charge for a minimum of four hours before attempting to power on; this brings the cell voltage above the recovery threshold and allows the BMS to resume normal operation.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Kangaroo
Fit Model
ePump Enteral Feeding Pumppump E-pump
Part Number
F0104841041411AMED0138B11404MED0138VMS1054715

Specifications

Battery typeNi-MH
Voltage4.8V
Capacity3500mAh
Wh16.8Wh
Dimensions69.40 x 46.53 x 33.70mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews