Compatible with KARL STORZ

KARL STORZ Surgical Headlight Replacement Battery - Replaces 094125A

$26.27In stock

Why this battery

  • Fits KARL STORZ Surgical Headlight model 094125A, OEM part number 094125A replacement battery.
  • 3.7V 1000mAh lithium-polymer cell delivers the power envelope this headlight requires for consistent illumination during surgical procedures.
  • Connector seats into the headlight charging port with positive contact alignment; no locking tab, straight insertion until seated.
  • We bench-tested this cell in the KARL STORZ charging cradle; BMS accepted the new pack on first insertion without fault codes.
  • After installation, allow the headlight to complete its power-on self-test cycle uninterrupted—medical devices run BMS verification at startup, and stopping this sequence causes false battery faults that persist until full reboot.
3.7V1000mAhLi-Polymer

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$26.27Quantity 1

About this replacement

KARL STORZ Surgical Headlight — 3.7V Li-Polymer Replacement Battery (094125A)

This 3.7V 1000mAh lithium-polymer cell is a direct replacement for the KARL STORZ surgical headlight battery identified by OEM part number 094125A. It fits the KARL STORZ headlight unit used for surgical and clinical illumination. Voltage and capacity match the original specification exactly — 3.7V, 1000mAh (3.7Wh).

  • 094125A platform fit: The KARL STORZ 094125A battery uses a lithium-polymer cell format at 3.7V. The headlight's BMS is calibrated to this voltage rail and cell chemistry. Substituting a different chemistry or nominal voltage trips a permanent battery fault in the device firmware.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on a controlled bench rig and monitored BMS handshake at each phase. The protection circuit responded correctly to charge termination and low-voltage cutoff. No false fault codes were logged during the test sequence.
  • Post-swap self-test completion: After fitting this battery, allow the headlight to complete its full power-on self-test without interruption. The device BMS runs a verification routine at startup to confirm cell chemistry and state of charge. Cutting power mid-sequence logs a battery fault that persists until the next clean reboot.

Why the 094125A headlight alarms low battery on a freshly charged cell

The KARL STORZ headlight BMS stores charge thresholds calibrated to the OEM cell's internal resistance profile. A new replacement cell has a slightly different resistance signature until it completes its first full charge-discharge cycle. The BMS interprets this mismatch as a low-state-of-charge condition and triggers the low battery alarm even at full voltage. Running one complete charge cycle — charge to cutoff, discharge under normal use, recharge fully — recalibrates the threshold and clears the alarm.

Headlight will not power on after the battery sat in storage

Lithium-polymer cells self-discharge during storage. If the cell voltage drops below approximately 3.0V, the headlight BMS enters a lockout state and refuses to boot — this is a protection mechanism, not a dead battery. Connect the headlight to its charger and leave it for a minimum of 30 minutes without attempting to power it on. The charge IC applies a low-rate recovery current first. Once cell voltage recovers above 3.2V, normal charging resumes and the device powers on.

Compatibility

Check your original model and part number before ordering.

Compatible brands
KARL STORZ
Fit Model
Surgical Headlight
Part Number
094125A

Specifications

Battery typeLi-Polymer
Voltage3.7V
Capacity1000mAh
Wh3.7Wh
Dimensions32.00 x 25.10 x 14.00mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews