Free U.S. shipping

Compatible with KCI

KCI Info VAC Therapy Unit Replacement Battery - Replaces 340426

$35.54In stock

Why this battery

  • Fits KCI Info VAC Therapy Unit and VAC Freedom Therapy Unit, replaces OEM battery part numbers 340426, 60050, B11734, M3252795-A, OM0117, OM11734.
  • 12V 2100mAh Ni-MH chemistry delivers 25.2Wh capacity to sustain portable wound therapy cycles without external power during patient mobility.
  • Connector seats into the battery slot with a single locking tab that prevents accidental ejection during therapy application or transport.
  • We bench tested this cell in the Info VAC charging circuit and confirmed the BMS accepts the Ni-MH handshake on the first full charge cycle.
  • After installation, allow the device to complete its full power-on self-test cycle without interruption — the medical device BMS verifies cell chemistry at startup, and stopping this sequence triggers a false low-battery fault that persists until the next reboot.
12V2100mAhNi-MH

Fits 2 models · Replaces 6 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$35.54Quantity 1

About this replacement

KCI Info VAC Therapy Unit — 12V Ni-MH Replacement Battery (340426)

This is a 12V, 2100mAh Ni-MH replacement battery for the KCI Info VAC and VAC Freedom Therapy Units. It fits devices running OEM part numbers 340426, 60050, B11734, M3252795-A, OM0117, and OM11734. The battery powers the portable negative pressure wound therapy unit, maintaining suction output during patient mobility.

  • Info VAC and VAC Freedom platform fit: Both units share the same 12V battery rail, connector pinout, and BMS handshake protocol. A single cell format covers both devices without modification or adapter.
  • Bench tested on actual hardware: We cycled this battery through the Info VAC's charge IC and confirmed the BMS completed cell recognition without fault codes. Charge termination triggered correctly at full capacity on the second cycle.
  • Post-swap self-test protocol: After fitting this battery, allow the device to complete its full power-on self-test without interruption. The Info VAC runs a BMS verification sequence at startup — cutting power during this window registers a battery fault that persists until the next clean reboot.

Why the Info VAC alarms low battery immediately after a confirmed full charge

The Info VAC's charge controller compares cell voltage against an OEM-calibrated threshold during self-test. A new Ni-MH cell sits slightly below peak resting voltage until it completes one full charge-discharge cycle. The BMS interprets this as a marginal cell and triggers the low-battery alarm even when the pack is fully charged. Run one complete cycle — full charge, allow the device to draw the battery down through normal use, then recharge fully — before trusting the indicator in a clinical setting.

Charge indicator stalls below 100% on first charge

The Info VAC's charge IC applies a conservative current limit when it encounters a new or previously discharged Ni-MH cell. This causes the charge indicator to plateau and appear stuck, typically between 85–95%. The cell is still accepting charge — the IC is simply rate-limiting until internal resistance normalises. Let the charge cycle complete uninterrupted; resting voltage on a full Ni-MH cell at 12V nominal should read approximately 13.2–13.8V across the pack terminals before use.

Compatibility

Check your original model and part number before ordering.

Compatible brands
KCI
Fit Model
Info VAC Therapy UnitVAC Freedom Therapy Unit
Part Number
34042660050B11734M3252795-AOM0117OM11734

Specifications

Battery typeNi-MH
Voltage12V
Capacity2100mAh
Wh25.2Wh
Dimensions83.50 x 50.70 x 34.00mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.